Tension Link WS Series wireless crane scale Technical
- 11 -
7. CALIBRATION
To set calibration, select cal parameter after selecting range
Press
key to confirm. Display of Tension Link indicator
This is common calibration, you can press
to choose linear calibration.
Common calibration: Span
Press
key to confirm. Tension Link displays uload.
Remove goods from the hook.
When weight is stable, press
key to confirm.
Tension Link display shows last calibrated test weight value
You can press
, or
M+
and
G/N
keys to change the value,
Press
key to confirm, Tension Link displays load
Add test weights to the hook,
When weight is stable, press
key to confirm.
Tension Link displays pass.
Then returns to the weight display.
Note 1:
If the Tension Link displays fail
It means calibration has failed, try repeating calibration, and verify you are
loading the correct weight.
Note 2: The calibration weight value should be less than or equal to scale
capacity, exceeding will cause the calibration sequence to fail.
cal
Commo
100.0
load
PAss
fail
uload