Tension Link WS Series wireless crane scale Technical
- 8 -
5.2 Accumulation
Tension Link WS can do accumulation, it can save 99 weighments of data.
5.2.1 Manual Accumulation
Accumulation Operation:
Ensure display is zero.
Place goods, when gets stable, Press
M+
key.
Remove goods from the hook, display of Tension Link indicator,
Followed by the total stored value
This will only display for 3 seconds
5.2.2 Memory Recall
In the weighing mode, when displaying value is zero or less than 20d,
press
M+
key, display of Tension Link indicator displays.
Total stored value will follow.
5.2.3 Memory Clear
In the weighing mode press
M+
key.
Display of Tension Link indicator.
Total stored value will follow.
Press
G/N
key, stored memory will be cleared.
Note: if you see
adder
, it means accumulation error, please make sure the
weight is more than 20d, or it will not perform accumulation.
5.3 Reading Lock or peak value
Read lock or peak value by pressing
key. press this key again to return
to normal display.
Note: enable/disable this function in parameter
P4 HLD
. (page 10)
When in peak/hold mode, peak/hold indication will turn on.
5.4 Change Weighing Unit
In normal display,
UNIT
key will change weighing unit: kg / g / oz / lb / N.
Note: enable/disable these units in parameter
F2 unt
0
100
N 001
100
N 001
100
N 001
100