Tension Link WS Series wireless crane scale Technical
- 9 -
6. PARAMETERS
Turn on the scale and press
key during the self-check, display will show
Press
key to change the menu selection.
Press
key to confirm;
Press
M+
key to increment digit position while entering numbers.
Press
UNIT
key to escape up a parameter level, then from the settings and
return to weighing mode. .
(Defaults are Bold)
Menu
Sub-Menu
Description
F0 off
Bk
Set
backlight
Bk on
Backlight always on
Bk of
Backlight always off
Bk au
Automatic backlight
Beep
Check
weighing
alarm
mode
off
Disable beeper
ok
beep when weighing value is in limit setting
ng
beep when weighing value is out of limit
setting
Off
Set auto
power off
0
Disable auto off function
3/5/15/30 Indicator will be auto off in 3/5/15/30 minutes
if it is not in use
F1 h-l
Sethi
Set high limit
Set high limit in check weighing mode
Setlo
Set low limit
Set low limit in check weighing mode
F2 unt
On /
off
g
Enable/disable:
g / lb / oz / Newton
On
/ off lb
On /
off
oz
On
/ off N
F3
com
Mode
off
Disable com port
Cont
Continuously stream weight data
F0 off