B-TEK Scales TensionLink WS Скачать руководство пользователя страница 12

Tension Link WS Series wireless crane scale Technical 

 

- 10 - 

AST 

R<013> Weight data on request 

Print 

Ptr 

LP50, TPUP 

Auto 

Baud 
(Data bit = 
8N1) 

See List 

1200/2400/4800/

9600

/19200/38400 

F4 ch 

Ch 1   ch2   ch3   Ch 4 
ch5   ch6     Ch 7   
ch8    

8 available channels, The Tension Link 
Remote should be the same as the Tension 
Link WS scale. 
CH1 430.000 MHz 
CH2 430.075 MHz 
CH3 430.150 MHz 
CH4  430.225 MHz 
CH5  430.300 MHz 
CH6  430.375 MHz 
CH7  430.450 MHz 
CH8  430.525 MHz

 

prog 

Pin 

Must be entered for 
access to parameters 
below 

Password is :  
TARE , M+ , ZERO 

P1 ref 

Azn 
 
Set auto 
zero 
tracking 

Off 

Disable zero tracking function 

0.5d 

 
Zero tracking range: 0.5d / 2d / 4d 

 2d 
 

4d 

0auto 
 
Set auto 
zero 
range 

P   0 

 
Auto zero range:  
 
   0 / 10 / 20 / 50 / 100 percent 

P  10 

P  20 

P  50 
P 100 

0range 
 
Set 
manual 
zero 
range 

P   0 

 
Manual zero range:  
 
   0 / 2 / 4 / 10 / 20 percent 

P   2 
P   4 
P  10 

P  20 

P2 cal 

Sigra 

desc 

Set decimal point: 

0

~0.0000 

Du ra 

inc 

Set increment: 1 / 2 / 5 / 10 / 20 / 50 

Du in 

cap 

Set capacity 

cal 

Enter calibration 

P3 inp  12345 

Internal counts 

P4 hld  Hold 

Enable hold function 

Peak 

Enable peak function 

 

Содержание TensionLink WS

Страница 1: ...Technical Manual TensionLink WS Wireless Crane Scale V1 16 ...

Страница 2: ...TION OF indicator 7 5 1 Basic Operation 7 1 Power On Off 7 2 Zero 7 3 Tare 7 4 Weighing Operation 7 5 2 Accumulation 8 5 2 1 Manual Accumulation 8 5 2 2 Memory Recall 8 5 2 3 Memory Clear 8 5 3 Reading Lock 8 5 4 Change Weighing Unit 8 6 PARAMETERS 10 7 CALIBRATION 12 8 DRAWINGS 14 9 CHANNEL 16 10 DIMENSIONS 17 ...

Страница 3: ...O SO COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT CAUTION Only qualified persons to service the instrument Before connecting or disconnecting any components remove the power Failure to observe these precautions bodily harm or damage to or destruction of the equipment Load the balance only in vertical travel direction Do not leave the controls while a load is suspended ...

Страница 4: ...les in water Do not stack material on the scales when they are not in use Never stand under the load or injury death may occur Read this manual before operating or repairing this equipment Follow these instructions carefully Disconnect the equipment from power source before maintaining The weighing indicator is a precision electronic instrument handle with care Verify the local voltage and recepta...

Страница 5: ...d 5000d Key Pad 7 Keys Indicator Power AC Adaptor 12V 500mA Battery 2000mAh 1 2Vx6 Interface RS 232 Output Optional Model Tension Link WS scale Display 23mm 9inch digit LCD display with white LED back light Scale Housing aluminum Operating Temperature 0 C 40 C 32 F 104 F Resolution 1000d 5000d Key Pad 1 Key on off key Scale Power AC Adaptor 9V 800mA Ni MH Battery 1 2Vx3 Removeable 3 AA batteries M...

Страница 6: ...st and accurate weighing by wireless communication It is used with the Tension Link WS crane scale Handheld indicator can be connected to a printer or a PC Large LCD with white LED back light display Battery provides up to 40 hours of continue use without backlight Wireless communication distance is up to 33 meters 100 feet ...

Страница 7: ... KEY FUNCTION Weighing mode Setting mode Power On Off Tare function Change selection Used to reset to Zero Enter Lock peak reading M Used to do accumulation if connected PC or printer it will send weighing data Move digit UNIT Change units Escape setting mode G N Change between Gross NET Clear active digit ...

Страница 8: ...al 6 Display DISPLAY FUNCTION ZERO Zero display indication OZT kg Unit indication HI OK LO Check weighing indication NET Net weight indication STABLE Stable indication M Accumulation indication Wireless connection indication Indication status of battery ...

Страница 9: ...any load 3 Tare The tare weight of a container can be set by pressing the button the net weight of the object is now displayed Apply tare weight to the hook Press key Zero is displayed and tare weight is subtracted Remove the container weight Negative tare weight is now displayed Only one tare value can be set To clear the tare value remove the load and press key Zero is displayed tare weight is c...

Страница 10: ...al stored value will follow 5 2 3 Memory Clear In the weighing mode press M key Display of Tension Link indicator Total stored value will follow Press G N key stored memory will be cleared Note if you see adder it means accumulation error please make sure the weight is more than 20d or it will not perform accumulation 5 3 Reading Lock or peak value Read lock or peak value by pressing key press thi...

Страница 11: ...k on Backlight always on Bk of Backlight always off Bk au Automatic backlight Beep Check weighing alarm mode off Disable beeper ok beep when weighing value is in limit setting ng beep when weighing value is out of limit setting Off Set auto power off 0 Disable auto off function 3 5 15 30 Indicator will be auto off in 3 5 15 30 minutes if it is not in use F1 h l Sethi Set high limit Set high limit ...

Страница 12: ...0 450 MHz CH8 430 525 MHz prog Pin Must be entered for access to parameters below Password is TARE M ZERO P1 ref Azn Set auto zero tracking Off Disable zero tracking function 0 5d Zero tracking range 0 5d 2d 4d 2d 4d 0auto Set auto zero range P 0 Auto zero range 0 10 20 50 100 percent P 10 P 20 P 50 P 100 0range Set manual zero range P 0 Manual zero range 0 2 4 10 20 percent P 2 P 4 P 10 P 20 P2 c...

Страница 13: ...on Link display shows last calibrated test weight value You can press or M and G N keys to change the value Press key to confirm Tension Link displays load Add test weights to the hook When weight is stable press key to confirm Tension Link displays pass Then returns to the weight display Note 1 If the Tension Link displays fail It means calibration has failed try repeating calibration and verify ...

Страница 14: ...ad intermediate weight 1 3 capacity or near 1 3 capacity when Tension Link display is STABLE Press to confirm Tension Link displays Load 2 Load intermediate weight 2 3 capacity or near 2 3 capacity when Tension Link display is STABLE Press to confirm Tension Link displays Load 3 Load full capacity when Tension Link display is STABLE Press to confirm Tension Link displays pass Then returns to the w...

Страница 15: ...NT COVER 1 ABS 3 899 300119 REMOTE OVERLAY UPPER DISPLAY 1 PC 4 899 300120 REMOTE OVERLAY LOWER KEYPAD 1 PC 5 N A DISPLAY SUPPORT 2 1 ABS 6 N A SCREW 4 M3x6 7 N A SCREW 10 M2 5x12 8 899 300125 SH WS TENSION LINK REMOTE MAINBOARD TECHNICIAN INSTALL REQUIRED SPLICE WIRES 1 9 N A SCREW 12 M3x8 10 N A GASKET 14 Paper M3 11 N A GASKET 6 Carbon Steel M3 ...

Страница 16: ...N A HANDLEBAR TAPE 1 Nylon 16 N A SCREW 4 M3x8 17 N A LOWER PLATE COVE 1 ABS 18 899 300126 WIRELESS MODULE FACTORY INSTALL REQUIRED PAIRED BOARD MUST REPLACE BOTH 1 19 N A NUT 1 M16 20 N A ANTENNA PROTECTIVE JACKET 1 ABS 21 899 300127 SH WS DISPLAY BOARD 1 22 899 300122 REMOTE CONTROL CHARGER 110VAC 12VAC 1 ABS 23 899 300121 SH WS TENSION LINK REPLACEMENT REMOTE CONTROL Complete Unit 1 Varies ...

Страница 17: ... BLOCK 1 Aluminum 5 N A ELASTOMER LOAD CELL 1 Aluminum 6 N A LOAD BUSHING 2 Aluminum 7 N A REAR COVER 1 Aluminum 8 N A SEAL COVER 1 Aluminum 9 899 300115 SCALE LINK UNIT CHARGER 110VAC 9VAC 1 ABS 10 899 300116 SH SH WS TENSION LINK SCALE LINK UNIT BATTERY 1 Ni MH 1 2Vx3 11 899 300118 SCALE OVERLAY W ON OFF BUTTON 1 PC 12 899 300124 SCALE MAINBOARD FACTORY INSTALL B TEK ONLY OVERLAY MUST BE REPLACE...

Страница 18: ...nnect CH2 K1 K2 connect K3 NC CH3 K1 NC K2 K3 connect CH4 K1 K3 NC K2 connect CH5 K1 K3 connect K2 NC CH6 K1 connect K2 K3 NC CH7 K1 K2 NC K3 connect CH8 K1 K2 K3 NC PRINT Example of Print M No 000 No 000 TOT W TOT W 000lb 000kg Example of Continuous String and AST String Send R 013 ST GS 000lb ST GS 000kg ST GS 000 example in Newtons ...

Страница 19: ...hnical 17 9 DIMENSIONS 1t 3t 5t 10t mm Inches mm Inches mm Inches A 99 5 3 9 99 5 3 9 99 5 3 9 B 30 1 2 30 1 2 40 1 6 C 55 6 2 2 61 6 2 4 71 6 2 8 D 165 6 5 165 6 5 185 6 5 E 90 3 5 90 3 5 90 3 5 F 255 10 265 10 4 275 10 8 G 32 1 25 30 1 18 40 1 57 ...

Страница 20: ...Tension Link WS Series wireless crane scale Technical 18 1t mm Inches A 256 10 1 B 226 8 9 C 88 3 5 D 68 2 7 E 136 5 4 F 68 2 7 G 64 2 5 H 180 7 1 ...

Страница 21: ...Tension Link WS Series wireless crane scale Technical 19 B TEK Scales LLC 1510 Metric Ave S W Canton OH 44706 Tel 330 471 8900 Fax 330 471 8909 www B TEK com ...

Отзывы: