Tension Link WS Series wireless crane scale Technical
- 10 -
AST
R<013> Weight data on request
Ptr
LP50, TPUP
Auto
Baud
(Data bit =
8N1)
See List
1200/2400/4800/
9600
/19200/38400
F4 ch
Ch 1 ch2 ch3 Ch 4
ch5 ch6 Ch 7
ch8
8 available channels, The Tension Link
Remote should be the same as the Tension
Link WS scale.
CH1 430.000 MHz
CH2 430.075 MHz
CH3 430.150 MHz
CH4 430.225 MHz
CH5 430.300 MHz
CH6 430.375 MHz
CH7 430.450 MHz
CH8 430.525 MHz
prog
Pin
Must be entered for
access to parameters
below
Password is :
TARE , M+ , ZERO
P1 ref
Azn
Set auto
zero
tracking
Off
Disable zero tracking function
0.5d
Zero tracking range: 0.5d / 2d / 4d
2d
4d
0auto
Set auto
zero
range
P 0
Auto zero range:
0 / 10 / 20 / 50 / 100 percent
P 10
P 20
P 50
P 100
0range
Set
manual
zero
range
P 0
Manual zero range:
0 / 2 / 4 / 10 / 20 percent
P 2
P 4
P 10
P 20
P2 cal
Sigra
desc
Set decimal point:
0
~0.0000
Du ra
inc
Set increment: 1 / 2 / 5 / 10 / 20 / 50
Du in
cap
Set capacity
cal
Enter calibration
P3 inp 12345
Internal counts
P4 hld Hold
Enable hold function
Peak
Enable peak function