28
BTEK T403S Indicator User Instructions
Indicator applications
3.6 Peak hold application
This section applies if your indicator has the Peak Hold application active.
3.6.1 SELECT key default function
In the Peak Hold application you can view the gross, max and min display values by
repeatedly pressing
SELECT
.
3.6.2 Special key functions
The following key has an extra function in this application:
F1
F1
resets the min and max peak weights to the current gross weight.
3.6.3 Peak hold operation
Only the highest weight applied to the scale is displayed when the peak weight value
is selected to be displayed. Minimum weight is designated by a pair of green
circle
annunciators. Maximum weight is designated by a different pair of green
circle
annunciators. See
.
Figure 3.3 Min/Max annunciators
With the Peak application active, follow these steps to perform and view peak
weighments.
1.
Repeatedly press
SELECT
until the two green circle annunciators on the right
light up. See
. This means you are now viewing the peak or maximum
weight.
2.
With no weight on the scale, press
ZERO
, if necessary press
F1
to reset any
previous peak value on the display.
3.
Place weight on the scale and then remove it …
The display will show the peak weight recorded during the weighment.
4.
To reset the peak, press
F1
…
The minimum and maximums are reset to the
current gross weight
.
lb
These two
annunciators light
for minimum weight
These two
annunciators light
for maximum weight
Содержание T403S
Страница 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Страница 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Страница 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Страница 73: ......
Страница 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...