BTEK T403S Indicator User Instructions
15
3.1 General weighing application
3.1.4 Using setpoints
Setpoints are values (weight) at which outputs are triggered automatically. Outputs can
control relays connected to valves, lights, other machinery, etc. Setpoint outputs can
be configured in the setpoint menu shown in
Figure 3.1 Setpoint menu
See the note below for an overview of how setpoints function.
The annunciator and output will turn on when weight goes above the setpoint for that
output and will remain on until the weight falls below the setpoint.
Follow these steps to configure the outputs:
1.
With the indicator powered up, press
SETUP
…
SEtPnt
is displayed. Refer to the Setpoint menu, shown in
while following the steps below
2.
Press
SELECT
…
out1
is displayed.
3.
Press
SELECT
…
Current value is displayed with the last digit flashing.
4a.
Key in a value and press
ZERO
to accept the value …
out1
is displayed.
out1
out2
out3
Setpnt
Key
in
setpoint
Key
in
setpoint
Key
in
setpoint
Press
SETUP
Default Setpoint operation
Outputs must be enabled for setpoints to operate. See the Service Manual
:
Below Configured Value:
Outputs are OFF
Annunciators are OFF
Above Configured Value:
Outputs are ON
Annunciators are ON
The setpoint outputs and setpoint annunciators logic state can be inverted
from their default settings to be ON when below and OFF when above the
configured value. Refer to details in the password protected menu settings in
the section titled
Содержание T403S
Страница 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Страница 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Страница 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Страница 73: ......
Страница 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...