Page | 36
iv. Click Ok to accept the changes and close the Network window
4. Close the Server window and tape on the Settings icon on the Database Page
5. Make a note of the Database Name field (default is STANDARD TRUCK.sdf)
6. Close the Settings page and reboot the primary indicator.
Setup Slave DD
1.
On the slave DD follow previous steps 3.I through 3.IV. However, this time set the
slave DD IP Address to 192.168.1.20 and a gateway of 255.255.255.0
2.
Under the Database Page tap the Settings icon
3.
Under the Database provider, select Remote
4.
Under Port Number enter 8095 (unless you changed it in step 2 of the primary
setup
5.
Under Data Source enter the IP Address from the primary DD, in this example it is
192.168.1.10
6.
Under Database Name enter the information collected in the primary setup step 5.
(Default is STANDARD TRUCK.sdf)
7.
Double check your settings and tap Ok
8.
Reboot the slave device, it should now be sharing a database with the primary
unit
a.
You can add additional slave devices to the mix by incrementing the IP
Address from step 1 of the slave setup and the rest of the setup.