8
SUBJCET TO CHANGE WITHOUT PRIOR NOTICE
FREEZING
' F '
A minimum water temperature < 2 is detected. C.
The activation date is recorded.
Temporary
Automatically when
the initial condition is
restored.
MAXIMUM FLOW
RATE EXCEEDED
' O '
The counter shall operate at a flow rate exceeding
Q4 for 10 consecutive minutes. The activation
date shall be recorded.
Permanent
Reset via NFC
or LORA.
LEAKAGE
' L '
The meter detects a continuous flow >0.5*Q1 for
12 hours. The alarm resets when the flow average
in 5 minutes is below the threshold indicated
above. The date of the resolved loss will then be
recorded. The threshold can be set via NFC or
LORA (minimum 1 hour).
Temporary
Automatically when
the initial condition is
restored.
BURST
' b '
The flow rate of the meter remains continuously
above Q3 for 30 minutes.
REVERSE FLOW
' I '
Continuous reverse flow greater than 200 liters.
Threshold can be set via NFC or LORA (minimum
20 liters). The activation date is recorded.
Permanent
Reset via NFC
or LORA.
NO CONSUMPTION
' c '
Flow detected for 7 consecutive days (minimum).
Threshold can be set via NFC or LORA.
Temporary
Automatically when
flow is detected.
RESET
' S '
Device restarted for any external cause.
Permanent
Reset via NFC
or LORA.
EXCESSIVE
TEMPERATURE
' h '
An ambient temperature of > 55 ºC is recorded.
The activation date is recorded.
END BATTERY LIFE
Low battery
Contact supplier
NFC FRAUD
' n '
Continuous NFC field detected for several
consecutive minutes.
Reset via NFC
or LORA.
RTC
' P '
Sudden reset of date and time detected.
Update date and time
via NFC or LORA.
6. Battery and replacement procedures
The water meter constantly monitors the status of the battery (total discharge: 13 years*) and signals the imminent discharge by
displaying the icon
. The report takes place one year before the total download. For replacement contact the manufacturer.
*Battery life depends heavily on the working time window, set during the configuration process, and the environmental
conditions. The battery life estimate is provided by the configuration software.
The meter uses non-rechargeable batteries that, if misused with, can be potentially dangerous.
To reduce the risks, you should take the following precautions:
Do not recharge or replace the battery
Do not open, puncture or damage batteries;
Do not short-circuit batteries;
Do not expose batteries to temperatures above 85 ºC;
Do not insert into ovens, crush or cut: these actions could cause an explosion or leakage of flammable gases or liquids.
Do not use naked flames near the device;
Do not put in contact with water;
Do not expose the battery to an extremely low pressure environment which could cause an explosion, a gas or flammable liquids leak;
Always dispose of batteries in compliance with current regulations;
Always use original spare parts authorized by the manufacturer;