SUBJCET TO CHANGE WITHOUT PRIOR NOTICE
If transmission network interfaces are used, especially when cables are routed outside the building, use more protection
against electrical interference.
In case of danger of frost, empty the system and, if necessary, remove the meter.
Rinse the pipes thoroughly before installing the meter.
The meter shall be installed in the direction of the arrow on the meter housing, corresponding to the direction of the flow.
Avoid collecting air bubbles in the meter during the installation process.
The meter shall not be subjected to mechanical stress when installed in the pipe.
The meter shall be installed in a way that it is protected from all external impurities and contamination.
Remove the old seals and clean the sealing surfaces.
Slightly grease the sealing surfaces (use grease approved for drinking water and acid-free).
The meter can only be installed in frost-proof areas.
Use only the gaskets supplied (the gaskets must not get into the pipe). Seals provided on site must be fit for purpose
and comply with local guidelines and directives. No liability is accepted for consequential damage resulting from the use
of third-party seals, such as corrosion of seal surfaces and threads.
Manually and simultaneously screw the meter fittings on both sides and then tighten in opposite
directions using a suitable tool.
Slowly fill the pipe with water after installation.
The meter must be protected against pressure shocks in the pipe.
The table below presents troubleshooting procedures:
Error
Cause
Troubleshooting
Display off
Batteries may be damaged or discharged.
Notify the service department
Damaged casing
Possible external impact or fall to
the ground
Lower case body separated
by electronic unit
Tampering by third parties or strong
external impacts
Open and visible electronic unit
Consumption is not accounted for
Tampering by third parties, strong external
impacts or flow detection sensor damage
Do not transmit radio signal
Flow failure of 5 liters or the batteries may
be damaged or discharged
Error ‘_ _ _ _ L Err’ present on display
Possible leakage in the water
supply/plant/taps
Check for leakage in the water
supply/system/tap
Error ‘_ _ _ _ O Err’ present on display
Range higher than Q4 for 10
consecutive minutes
Error ‘_ _ _ _ I Err’ present on display
Continuous reverse flow greater
than 20 liters
Installations requirements
All water meter versions can be installed both horizontally and vertically.
H
↑
H
→
H
↓
V