TEMPERATURE INPUT CONFIGURATION
Temperature inputs can be Enabled/Disabled. It’s recommended that you disable all unused inputs to
save on wireless traffic and battery life. Temperature inputs are Enabled by default.
Temperature MQTT publishes can be set to either Celsius or Fahrenheit. Temperature readings are set to
Celsius by default.
Click to review and save any changes.
HUMIDITY INPUT CONFIGURATION
Humidity inputs can be Enabled/Disabled. It’s recommended that you disable all unused inputs to save on
wireless traffic and battery life. Humidity inputs are Enabled by default.
COPYING NODE CONFIGURATIONS
If more than one node is used to monitor the same type of asset, it is simpler to copy configurations
between nodes than to set up each node individually. Once a node and all its I/O have been configured,
you can copy that configuration to any other nodes of the same model.
1. In the tree, select the configured node you wish to copy and click the Replicate Settings button.