Proprietary
7
DMOC445 Manual and Operating Instructions
cells, but special protections are needed in such cases in order to ensure the safety of
the DMOC and ESS.
On the AC-side, the DMOC connects to a Azure Dynamics supported three-phase motor,
such as an AC Induction Motor or Permanent Magnet Motor. Specific instructions on how
to safely install the DMOC and make the necessary electrical connections are given in
this document. Since the DMOC is part of a high-voltage system it is extremely important
the directions of the document are followed and that only personnel trained to work with
high voltage install and maintain this product.
Figure
with typical DMOC connections
Azure’s PC based diagnostics/calibration tool ccShell allows to access and modify DMOC
calibrations and to visualize and capture signals in real-time. While the meaning of the
most important calibrations and signals of the DMOC core is described in this document,
the reader is referred to the ccShell manual for information on how to install and use this
tool.