Proprietary
35
DMOC445 Manual and Operating Instructions
9. Grounding and Shielding
One of the more important factors in the design and maintenance of vehicle electric traction system is
proper shielding and grounding. Inadequate shielding or grounding can lead to unreliable operation of
systems, such as EMI, electrostatic discharge damage to sensitive electronics and personnel shock
hazard. Perform all grounding and shielding connections as shown on the following diagram.
Figure 9. DMOC Grounding and Shielding.
T1
T2
T3
AC MOTOR
CASE
A
+
B
-
C
CASE
CASE
DMOC 445
4AWG
SHLD
4AWG
4AWG
STATOR
4AWG
5/8 TB BR
R 2AWG
BK 2AWG
VEHICLE
CHASSIS
Figure 10. Example of the DMOC Grounding Strap Connection.