B-14
Display Transducer Block
INDEX Parameter name
Description
Sub-parameter
name
Access
attribute
Size
(Byte)
Range
Factory default
setting
1
ST_REV
Indicates the number of changes of the
Static parameter that belongs to DISPLAY_
TB. It is incremented by one (0x0001)
when a change is made for a parameter
whose access attribute is “S-.”
-
S-R
2
0 ≤ X ≤ 65535
0
2
TAG_DESC
The tag name of DISPLAY_TB set by
the user. It can be referenced by the host
devices and thus does not affect the
execution of Function block operation at
all.
-
S-R/W
32
spaces
3
STRATEGY
An arbitrary group number for DISPLAY_
TB. It does not affect Function block
operation.
-
S-R/W
2
0
4
ALERT_KEY
An identification number of the relevant
in-plant device. It does not affect Function
block operation.
-
S-R/W
1
1 ≤ X ≤ 255
0
5
MODE_BLK
Indicates the mode parameter group of
DISPLAY_TB. The configuration is as
follows:
· Target: Parameter for setting mode from
host devices.
· Actual: Indicates the current value of the
mode.
· Permitted: Indicates the mode value used
for the Function block.
· Normal: Indicates the mode value which
should be in a steady state.
Target
N-R/W
1
O/S, AUTO
bit3:AUTO
0x08
Actual
D-R
1
-
Permitted
S-R/W
1
bit3:AUTO
bit7:O/S
0x88
Normal
S-R/W
1
bit3:AUTO
0x08
6
BLOCK_ERR
Indicates the error state regarding
DISPLAY_TB.
-
D-R
2
bit0: Other
bit1: Block Configuration Error
bit15: Out-of-Service
-
7
UPDATE_EVT
Parameter for generating an alert when
fixed data (data whose access attribute is
“S-” or “N-”) of DISPLAY_TB is changed.
The configuration is as follows:
· Unacknowledged: Determined state
· Update_State: Change state
· Time_stamp: Change time
· Static_Revision: Revision after change
· Relative_Index: Changed parameter
identification number
Unacknowledged D-R/W
1
(0: Undefined)
1: Acknowledged
2: Unacknowledged
-
Update State
D-R
1
0: Undefined
1: Update reported
2: Update not reported
-
Time Stamp
D-R
8
-
Static Revision D-R
2
-
Relative Index
D-R
2
-
8
BLOCK_ALM
Parameter that indicates the configuration
regarding DISPLAY_TB and the abnormal
state in execution. The configuration is as
follows:
· Unacknowledged: Generation determined
state
· Alarm_State: Alarm generation state
· Time_stamp: Alarm generation/recovery
time
· Subcode: Alarm content sub-code
· Value: Alarm value
Unacknowledged D-R/W
1
(0=Undefined)1=Acknowledge
d2=Unacknowledged
-
Alarm State
D-R
1
0=Undefined1=Clear
- reported2=Clear -
not reported3=Active -
reported4=Active - not
reported
-
Time Stamp
D-R
8
-
Subcode
D-R
2
-
Value
D-R
1
-
9
TRANSDUCER_
DIRECTORY
The header information of DISPLAY_TB.
Users do not directly use this parameter.
-
S-R
2
0
10
TRANSDUCER_
TYPE
Indicates the type of DISPLAY_TB.
-
S-R
2
0xffff
11
TRANSDUCER_
TYPE_VER
Indicates the version of DISPLAY_TB.
-
N-R
2
-
12
XD_ERROR
Indicates an abnormal state specific to the
device.
-
D-R
1
19: Configration Error
-
13
COLLECTION_
DIRECTORY
Definition information of the parameter
group for efficient access of the host
devices to parameters having the same
attribute.
-
S-R
4
0
Содержание MagneW Plus+ MGG14C
Страница 6: ...iv ...
Страница 8: ...vi ...
Страница 11: ...1 3 Figure1 3 System using a Foundation Fieldbus ...
Страница 14: ...1 6 The following table is a summary of the functions of each of the keys ...
Страница 20: ...1 12 CALIBRATION OFF SHIPPING INFO OFF MAINTENANCE MODE MODE RETURN BASIC SETUP Figure1 10 MAINTENANCE MODE ...
Страница 26: ...2 6 ...
Страница 42: ...4 6 ...
Страница 78: ...A 10 ...
Страница 105: ......
Страница 108: ......
Страница 110: ......