Azbil INFILEX GC WY5311 Скачать руководство пользователя страница 9

AB-6580 

Connection of Data Setter for LonTalk Protocol 

Connect the CompactFlash

®

 memory type Data Setter (Model QY5111B) for LonTalk protocol to LC-bus port or to CONF. port of 

Infilex GC with the Data Setter adaptor (Part No. DY5301S0000, with separate order required.). 
For details of the Data Setter adaptor, refer to its Specifications manual. 

LC-bus 

(LonTalk  

 

 

 

       (For setting Infilex GC and other remote units connected on both 

protocol) 

 

 

 

       LC-bus and LS-bus:  Connect Data Setter with Data Setter adaptor to 

LC-bus port or CONF. port of Infilex GC.) 

 
 
 
 
 
 
 
 
 
 
 
       LS-bus 

(LonTalk 

protocol) 

 
 

 
 
 

Figure 6.  Connection example of Data Setter with Data setter adaptor to LC-bus port/CONF. port 

 

Infilex AC 

Model WY5317

 

Infilex GC 

Model WY5311

 

Infilex GD 

Model WY5310

 

Data Setter 

adaptor 

Model DY5301S 

Data Setter

Model QY5111B

Infilex ZM 

Model WY5322

 

Infilex SC

Model WY5307

Infilex FC 

Model WY5305

Infilex VC 

Model WY5306

Содержание INFILEX GC WY5311

Страница 1: ...ed in terms of both the software and hardware Features Compact design Small size body allows free installation in a desired place Various input output I O configurations Input and output types can be...

Страница 2: ...les Use crimp terminal lugs with insulation for electric wires connected to the screw terminals Connect cables to the power source with terminals or the like for permanent connection Make sure all the...

Страница 3: ...e Digital user terminal Analog user terminal Figure 2 System configuration example of standalone Infilex GC Notes On LS bus max 50 controllers can be connected Max wiring length of LS bus is 900 m Inf...

Страница 4: ...odules to be combined with Model WY5311 refer to AB 6527 Specifications Instructions of Model RY50XX Parts for Installation For details regarding Infilex GC installation refer to Installation manual o...

Страница 5: ...Transmit RX Receive SERV Service RAM RTC Lithium battery backup Power failure backup Data file Non volatile memory flash memory backup Transmission system LonTalk protocol TP FT 10 transceiver Transmi...

Страница 6: ...fications of I O modules user interface modules and Operator Panel For the specifications of I O modules and user interface modules refer to Specifications Instructions of Model RY50XX AB 6527 For the...

Страница 7: ...AB 6580 7 Dimensions Figure 4 Dimensions mm 60 90 140...

Страница 8: ...See Table 2 for SERV LED operation Major alarm initializing ERR1 ON Minor alarm initializing ERR2 ON Table 2 Indication and operation of SERV LED Status LED indication ON OFF Normal Normal Application...

Страница 9: ...LC bus LonTalk For setting Infilex GC and other remote units connected on both protocol LC bus and LS bus Connect Data Setter with Data Setter adaptor to LC bus port or CONF port of Infilex GC LS bus...

Страница 10: ...ON If the product has never or hardly been operated in OFF state for a year replace the lithium battery before the product operation Battery replacement Replace the lithium battery with Infilex GC in...

Страница 11: ...Several tens of seconds are required for the product normal operation after the power is turned on During this time the ERR1 LED red for major alarm lights up temporarily but this does not indicate a...

Страница 12: ...AB 6580 Specifications are subject to change without notice Building Systems Company http www azbil com Rev 4 0 Sep 2015 AB 6580 H W03 J AI 6580 Rev 3 1 Printed in Japan 12...

Отзывы: