![Azbil dcp551 mark II Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/azbil/dcp551-mark-ii/dcp551-mark-ii_user-manual_3042608157.webp)
8-17
■
Setting cycle items
(1) In the set value display state, move to the cycle item to be set for the segment
on the programming map.
(A cycle item is a program setting and is the same for each segment.)
(2) Press the
ENTER key
to make display panel 2 flash (registration of first
setting).
(3) Use
the , , ,
and
keys
to make the first setting – setting the cycle
value.
Setting range: 0 to 10000
(4) Press the
ENTER key
to stop the flashing on display panel 2.
(Pressing the
FUNC
and
CLR keys
causes display panel 2 to return to unset
state “
0
” and the flashing stops.)
●
Display
• A cycle item is a program setting and is the same for each segment.
• When setup data
C60
is set to 1, a cycle item on the programming map is
skipped and not displayed.
NOTE
A cycle item setting does not use subfunctions.
PROG
SEG
PROFILE
Program
number
Segment
number
Pattern trend
P R O G R A M C Y C L E
Set cycle count value
Chapter 8. PROGRAM SETUP