Display
Item
Contents
Initial value Setting value
Key oper
ation • displa
y
C75
MV display setup
(Sum of the weighting)
Bit 0: MV display (Enabled: +1)
Bit 1: Heat MV/cool MV display (Enabled: +2)
Bit 2: MFB display (Enabled: +4)
Bit 3: AT progress display (Enabled: +8)
15
C76
Event setting value display
setup (Operation display)
0: Not displayed
1: Set value of Internal event 1 is displayed
2: Set values of Internal event 1 to 2 are displayed
3: Set values of Internal event 1 to 3 are displayed
0
C77
Event remaining time display setup
(Operation display)
0: Not displayed 1: Internal event 1 is displayed
2: Internal event 1 to 2 is displayed
3: Internal event 1 to 3 is displayed
0
C78
CT input current value display setup
(Operation display)
0: Not displayed 1: CT1 current value is displayed
2: CT1 to 2 current values are displayed
0
C79
User level
0: Simple configuration 1: Standard configuration
2: High function configuration
1
C80
LED monitor
0: Not used
1: Flashing while data is sending through RS-485 communication.
2: Flashing while data is receiving through RS-485 communication.
3: Logical OR of all DI statuses 4: Flashing in READY mode
0
C8
1
MS indicating lamp ON condi-
tion (1st priority)
0: Normally OFF 1: Normally ON 2 to 9: Internal event 1 to 8
10 to 13: Undefined 14: MV1 15: MV2 16 to 17: Undefined
18 to 21: DI1 to 4 22 to 25: Undefined
26 to 30: Internal contact 1 to 5 31 to 33: Undefined
34 to 37: Communication DI 1 to 4 38: MANUAL 39: READY
40: RSP 41: AT 42: During ramp 43: Undefined 44: Alarm
45: PV alarm 46: Undefined 47: [mode] key pressing status
48: Event output 1 terminal status 49: Control output 1 terminal status
39
C82
MS indicating lamp ON status
(1st priority)
0: lit 1: Slow flashing 2: Flashing twice
3: Fast flashing 4: Left to right 5: Right to left
6: Reciprocating between left and right 7: Deviation OK
8: Deviation graph 9: MV graph 10: Heat-side MV graph
11: Cool-side MV graph 12: MFB graph 13: DI monitor
14: Internal contact monitor 15: Internal event monitor
1
C83
MS indicating lamp ON condi-
tion (2nd priority)
Same as MS display, Condition (1st priority)
44
C84
MS indicating lamp ON status
(2nd priority)
Same as MS display, Status (1st priority)
6
C85
MS indicating lamp ON condi-
tion (3rd priority)
Same as MS display, Condition (1st priority)
1
C86
MS indicating lamp ON status
(3rd priority)
Same as MS display, Status (1st priority)
9
C87
MS indicating lamp deviation range 0 to 9999U
5
C88
Special function
0 to 15 (This value becomes "0" when the power is turned ON.)
0
C89
Zener barrier adjustment
The value can be changed with the adjustment. The numeric
value cannot be directly input with the manual operation.
0.00
C90
Number of CT1 turns
0: 800 turns 1 to 40: CT turns divided by 100
8
C9
1
Number of CT1 power wire loops 0: 1 time 1 to 6: Number of times
1
C92
Number of CT2 turns
0: 800 turns 1 to 40: CT turns divided by 100
8
C93
Number of CT2 power wire loops 0: 1 time 1 to 6: Number of times
1
C97
PV input failure (under range)
type *
1
0: -10 %FS
1: -5 mV (This setting is applicable if C01 (PV input range
type) is set for sensor type B (No.17) or PR40-20 (No. 23))
0
*1 Cannot be selected if ROM version 1 (
i
d02
) of the instrument information bank is 2.26 or earlier.
EvCF
[Event configuration bank]
Display
Item
Contents
Initial value Setting value
E
1.C
1
to
E8.C
1
Internal event 1 to 8 Configuration 1 Refer to event type (see page 8)
0
E
1.C2
to
E8.C2
Internal event 1 to 8 Configuration 2 The digits are determined to 1st, 2nd, 3rd, and
4th digit from the right end.
1st digit: Direct/Reverse
0: Direct 1: Reverse
0
2nd digit: Standby
0: None 1: Standby 2: S Standby at SP change
0
3rd digit: EVENT state at READY 0: Continue 1: Forced OFF
0
4th digit: Undefined
0
0
E
1.C3
to
E8.C3
Internal event 1 to 8 Configuration 3 The digits are determined to 1st, 2nd, 3rd, and
4th digit from the right end.
1st digit: Alarm OR
0: None 1: Alarm OR operation
2: Alarm AND operation
3: Alarm r OR operation
4: Alarm r AND operation
0
2nd digit: Special OFF
0: As usual
1: When the event set value (main setting) is 0, the event is "OFF".
0
3rd digit: Delay time unit
0: 0.1s 1: 1s 2: 1min
0
4th digit: Undefined
0
0
di
[DI assignment bank]
Display
Item
Contents
Initial value Setting value
dI
1
.
1
to
dI
5.
1
Internal contact 1 to 5
Operation type
0: No function 1: LSP group selection (0/+1)
2: LSP group selection (0/+2) 3: LSP group selection (0/+4)
4: PID group selection (0/+1) 5: PID group selection (0/+2)
6: PID group selection (0/+4) 7: RUN/READY selection
8: AUTO/MANUAL selection 9: LSP/RSP selection
10: AT Stop/Start 11: Invalid 12: Control action direct/reverse
13: SP Ramp enabled/disabled 14: PV Hold
15: PV Maximum value hold 16: PV Minimum value hold
17: Timer Stop/Start 18: Release all DO latches (Continue/Release)
19: Advance 20: Step hold
0
dI
1.2
to
dI
5.2
Internal contact 1 to 5
Input bit operation
0: Not used (Default input) 1: Function 1 ((A and B) or (C and D))
2: Function 2 ((A or B) and (C or D)) 3: Function 3 (A or B or C or D)
4: Function 4 (A and B and C and D)
0
dI
1.3
to
dI
5.3
Internal contact 1 to 5
Input assignment A
0: Normally opened 1: Normally closed 2: DI1 3: DI2
4: DI3 5: DI4 6 to 9: Undefined
10 to 17: Internal event 1to 8
18 to 21: Communication DI1 to 4 22: MANUAL 23: READY
24: RSP 25: AT running 26: During SP ramp
27: Undefined 28: Alarm occurs 29: PV alarm occurs
30: Undefined 31: mode key pressing status
32: Event output 1 status 33: Control output 1 status
2 to 5
or 0
dI
1.4
to
dI
5.4
Internal contact 1 to 5
Input assignment B
0
dI
1.5
to
dI
5.5
Internal contact 1 to 5
Input assignment C
0
dI
1.6
to
dI
5.6
Internal contact 1 to 5
Input assignment D
0
dI
1.7
to
dI
5.7
Internal contact 1 to 5
Polarity A to D
The digits are determined to 1st, 2nd, 3rd and
4th digit from the right end.
1st digit: Polarity A
0: Direct 1: Reverse
0
2nd digit: Polarity B
0
3rd digit: Polarity C
0
4th digit: Polarity D
0
dI
1.8
to
dI
5.8
Internal contact 1 to 5 Polarity 0: Direct 1: Reverse
0
dI
1.9
to
dI
5.9
Internal contact 1 to 5
Internal event No. assignment
0: Every Internal Event
1 to 8: Internal Event No.
0
dO
[DO assignment bank]
Display
Item
Contents
Initial value Setting value
Ot
1.
1
to
Ot2.
1�
Ev
1.
1
to
Ev3.
1
Control output 1 to 2, event
output 1 to 3 Operation type
0: Default output 1 to 2: MV1 to 2
3 to 6: Function 1 to 4
0
Ot
1.2
to
Ot2.2�
Ev
1.2
to
Ev3.2
Control output 1 to 2, event
output 1 to 3 Output assign-
ment A
0: Normally opened 1: Normally closed
2 to 9: Internal Event 1 to 8 10 to 13: Undefined
14 to 15: MV1 to 2 16 to 17: Undefined
18 to 21: DI1 to 4 22 to 25: Undefined
26 to 30: Internal Contact 1 to 5
31 to 33: Undefined 34 to 37: DI1 to 4 38: MANUAL
39: READY 40: RSP mode 41: AT running
42: During SP ramp 43: Undefined
44: Alarm occurs 45: PV alarm occurs
46: Undefined 47: Mode key pressing status
48: Event output 1 status 49: Control output 1 status
14: Output 1
15: Output 2
2: Event 1
3: Event 2
4: Event 3
Ot
1.3
to
Ot2.3�
Ev
1.3
to
Ev3.3
Control output 1 to 2, event output
1 to 3 Output assignment B
0
Ot
1.4
to
Ot2.4�
Ev
1.4
to
Ev3.4
Control output 1 to 2, event output
1 to 3 Output assignment C
0
Ot
1.5
to
Ot2.5�
Ev
1.5
to
Ev3.5
Control output 1 to 2, event output
1 to 3 Output assignment D
0
Ot
1.6
to
Ot2.6�
Ev
1.6
to
Ev3.6
Control output 1 to 2, event
output 1 to 3 Polarity A to D
The digits are determined to 1st, 2nd, 3rd, and
4 th digit from the right end.
1st digit: Polarity A
0: Direct
1: Reverse
0
2nd digit: Polarity B
0
3rd digit: Polarity C
0
4the digit: Polarity D
0
Ot
1.7
to
Ot2.7�
Ev
1.7
to
Ev3.7
Control output 1 to 2, event
output 1 to 3 Polarity
0: Direct
1: Reverse
0
Ot
1.8
to
Ot2.8�
Ev
1.8
to
Ev3.8
Control output 1 to 2, event
output 1 to 3 Latch
0: None 1: Latch (Latch at ON)
2: Latch (Latch at OFF except for initialization at power ON)
0
UF
[User function bank]
Display
Item
Contents
Initial value Setting value
UF-
1
to
UF-8
User function 1 to 8
–
–
LOC
[Lock bank]
Display
Item
Contents
Initial value Setting value
LOC
Key lock
0: All settings are possible
1: Mode, event, operation display, SP, UF, lock,
manual MV can be set
2: Operation display, SP, UF, lock, manual MV can be set
3: UF, lock, manual MV can be set
0
C.LOC
Communication lock
0: read/write enabled 1: read/write disabled
0
L.LOC
Loader lock
0: read/write enabled 1: read/write disabled
0
PASS
Password display
0 to 15 (5: Password 1A to 2B display)
0
PS
1A
Password 1A
0000 to FFFF (Hexadecimal value)
0000
PS2A
Password 2A
0000 to FFFF (Hexadecimal value)
0000
PS
1b
Password 1B
0000 to FFFF (Hexadecimal value)
0000
PS2b
Password 2B
0000 to FFFF (Hexadecimal value)
0000
I
d
[Instrument information bank]
Display
Item
Contents
Initial value Setting value
I
d0
1
ROM ID
2: Fixed
0
I
d02
ROM Version 1
XX. XX (2 digits after decimal point)
–
I
d03
ROM Version 2
XX. XX (2 digits after decimal point)
–
I
d04
Loader information
–
I
d05
EST information
–
I
d06
Manufacturing date code
(year)
Subtract 2000 from the year.
Example: "3" means the year 2003.
–
I
d07
Manufacturing date code
(month, day)
Month + day divided by 100.
Example: "12.01" means the 1st day of December.
–
I
d08
Serial No.
–
Precaution for setup
•
The type of auto tuning can be changed by changing the value of
At.ty
(AT type) in the extended tuning bank. Set it to match the
control characteristics.
•
Make sure that the motor will be adjusted. Set
C60
(Motor auto
adjust) in [Setup bank] to “1” (Start).
•
For position proportional control models, derivative time (D) will
be 0 seconds when AT is complete. If satisfactory control results
cannot be obtained, set
At-d
(AT derivative time adjust) in
[Extended tuning bank] to “1.00.”
Memo
Changing the user level
This controller's user level can be set to 1 of 3 types in setup
C79
.
The number of possible displays and settings decreases according
to the user level: high function > standard > simple. All items are
displayed when high function is selected.
1
Press [display] once
to get the operation
display.
Next, press and hold
[para] for more than 2s
to get the parameter
setup display.
MOde
flashes on the upper
display.
2
Press [ ] or [ ] repeat-
edly as needed to get
STUP
flashing on the
upper display.
3
Press [enter].
C0
1
is shown on the
upper display.
Press [<], [ ] or [ ] to
change to
c79
(user
level).
4
When [enter] is
pressed, the lower
display flashes.
Press [ ] or [ ] to
change to the desired
setting, and press
[enter] to finalize your
selection.
0: Simple configuration
1: Standard configuration
(initial value)
2: High function configuration
• Items marked
in the tables are displayed in standard and/or high function configuration.
• To change a user level, refer to
Changing the user level
in the lower right part of this page.