Flowchart of key operations and displays

Upper and lower displays 
remain off for 5s after 
power ON. Each mode 
indicator lights sequentially, 
and then the operation 
display appears.

User 

function

When the power 

is turned ON

[display] key

[para] key

[display] key

[para] key

*

1

PV value

[display] key

SP value

(2)

(1)

LSP group 

number

SP value

Step No.

Step remaining 

time

PV value

MV value

Timer remaining 

time 3

Internal event 3 

delay time

Internal event 3 

sub-setting

Setting value

Internal event 3 

main setting

Setting value

[SP]

[Event]

[PID]

[Parameter] [Extended tuning]

2-second press + hold 

of [para] key

[display] key

*

3

[Mode]

2-second press + 

hold of [para] key

[para] key

or

[ ] key

[enter] key

[ ] key

While 

AUtO

 

is flashing, 

[enter] key

While 

MAn

 

is flashing, 

[enter] key

to 

(1)

(MANUAL)

(AUTO)

[para] key or 

[ ] key

to 

(2)

[Zone]

[enter] 

key

[ ] key

Timer remaining 

time 2

Internal event 2 

delay time

2-second 

press + hold 

of [para] key

Содержание C35

Страница 1: ...en left and right it performs MV graph DI monitor internal event monitor and other display functions Mode indicators man Lights when MANUAL AUTO mode if not lit rsp Lights when RSP LSP mode if not lit ev1 ev2 ev3 Lights when event relays are ON ot1 ot2 Lights when the control output is ON always lit when the current output is used mode key When this key is pressed and held for more than 1 second i...

Страница 2: ... No Step remaining time PV value MV value Timer remaining time 3 Internal event 3 delay time Internal event 3 sub setting Setting value Internal event 3 main setting Setting value SP Event PID Parameter Extendedtuning 2 second press hold of para key display key 3 Mode 2 second press hold of para key para key or key enter key key While AUtO is flashing enter key While MAn is flashing enter key to 1...

Страница 3: ...b setting Setting value Internal event 2 main setting Setting value Timer remaining time 1 Internal event 1 delay time Internal event 1 sub setting Setting value Internal event 1 main setting Setting value Coolmanipulated variable MV value MFB MFB value Setup Lock key enter key Instrumentinformation 2 second press hold of para key Event configuration DIassignment DO assignment User function para k...

Страница 4: ...ulate PID values Check that this operation does not create any problems for the as sociated equipment before executing AT 1 Press display once to get the operation display 2 Press and hold para for more than 2s to get the parameter setup display MOde flashes on the upper display 3 Press enter or to get A M on the upper display and autO on the lower display If the control method is ON OFF control a...

Страница 5: ... Press or to get 1 Press enter and auto adjustment starts 6 CA CL is displayed on the upper display and open contact is ON The lower display shows the MFB count value and when count is stable CA OP is dis played on the upper diplay and closed con tact is ON When the count value is stable auto adjust completes to get op eration display After starting auto adjust press display key to stop auto adjus...

Страница 6: ...D Conventional PID 1 Ra PID High performance PID 0 JF Ov Just FiTTER assistance coefficient 0 to 100 0 1 Normal Standard control characteristics Immediate response Control characteristics that respond immediately to external disturbance Stable Control characteristics having less up down fluctuation of PV ZOne Zone bank Display Item Contents Initial value Settingvalue ZO 1 to ZO 7 Zone 1 to 7 1999 ...

Страница 7: ...ication DI1 to 4 22 MANUAL 23 READY 24 RSP 25 AT running 26 During SP ramp 27 Undefined 28 Alarm occurs 29 PV alarm occurs 30 Undefined 31 mode key pressing status 32 Event output 1 status 33 Control output 1 status 2 to 5 or 0 dI 1 4 to dI 5 4 Internal contact 1 to 5 Input assignment B 0 dI 1 5 to dI 5 5 Internal contact 1 to 5 Input assignment C 0 dI 1 6 to dI 5 6 Internal contact 1 to 5 Input a...

Страница 8: ... or 2 or both A current exceeding the upper limit of the display range was measured The number of CT turns or the number of CT power wire loops is incorrectly set or wiring is incorrect Use a CT with the cor rect number of turns for the display range Reset the number of CT turns Reset the number of CT power wire loops Check the wiring Unit failure AL70 A D conversion failure A D converter is fault...