background image

AB-6208-U 

100

 
 
 

75

 
 
 

50

 
 
 

25

 
 
 

0

  25 50 75 100

Cv (%)

Valve position (%) 

Parts 

Identification 

   Flow 

Characteristic 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

Figure 2.  Parts identification  

 

 

 

Figure 3.  Flow characteristic diagram 

 

 

Installation 

 CAUTION 



Install and use this product under the operating conditions (for temperature, humidity, power, vibration, shock,
mounting direction, atmosphere, etc.) listed in the specifications. Failure to do so might cause fire or device failure. 



Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards.



Do not use the product in an atmosphere corrosive to the actuator, valve, and their components. Doing so might 
damage the product. 



For installation, do not mount the valve in an improper position or overtighten the threaded connections. Doing so 
might damage the product. 



Do not excessively screw a pipe into the valve. Doing so might damage or deform the inside of the valve causing 
leakage and malfunction. 



Install the product so that no foreign objects remains inside the pipes. Be sure to provide a strainer on the inflow side
of the piping. Flush the piping to remove the foreign objects after installation. Foreign objects inside the piping might
damage the product. 



After installation, make sure no fluid leaks from the valve-pipe connections. Incorrect installation might cause fluid 
leakage. 

 

  To remove foreign substances inside the pipes, install a strainer on the inflow side of each valve. In case that the strainers 

cannot be installed on the inflow side of each valve, install it on the pipe diverting sections (sections diverting from main 
piping system to sub piping system). 

  Install the valve so that the flow direction of process fluid agrees with the arrow indicated on the valve body. 

 

 

 

 

 

 

 

Содержание ACTIVAL VY5302B

Страница 1: ...ed space such as inside of a compact AHU Bronze valve body applicable to 230 psig Easy assembly with Model MY53X0A actuator using no tool and no adjustment required Equal percentage flow characteristic AHU Air handling unit This product was designed and manufactured conforming to the ISO International Organization for Standardization PN16 Model Numbers Base model number Material Size Cv Descriptio...

Страница 2: ...tmosphere etc listed in the specifications Failure to do so might cause fire or device failure Use the product within its lifespan and avoid instrumentations that keep the product to operate excessively Continued use beyond the lifespan might cause fire or device failure Keep the products in package for storage Failure to do so might damage or stain the products Installation and wiring must be per...

Страница 3: ...Valve size Cv close off rating Model number Nominal size Cv Close off rating Inch DN VY5302B0011 1 2 15 2 5 145 psig VY5302B0012 1 2 15 4 145 psig VY5302B0022 3 4 20 6 3 145 psig VY5302B0023 1 25 10 145 psig VY5302B0031 1 1 4 32 16 72 psig VY5302B0041 1 1 2 40 25 72 psig VY5302B0042 1 1 2 40 40 72 psig Materials Body Cast bronze Cap Cast bronze Seat ring Carbon Reinforced PTFE Ball Cast stainless ...

Страница 4: ...ons Doing so might damage the product Do not excessively screw a pipe into the valve Doing so might damage or deform the inside of the valve causing leakage and malfunction Install the product so that no foreign objects remains inside the pipes Be sure to provide a strainer on the inflow side of the piping Flush the piping to remove the foreign objects after installation Foreign objects inside the...

Страница 5: ...the inflow outflow and bypass sides Also install a strainer with 40 or more meshes on the inflow side When installing the valve to pipes do not allow any object such as chips to get inside a pipe or valve Valve cannot fully closes or the valve seat may get damaged causing fluid leakage due to an foreign object jammed inside the valve When piping do not apply too much sealing material such as solid...

Страница 6: ...ositions of the actuator and the valve as follows referring to Fig 7 Actuator Indicator manual lever points at 100 fully open position Valve An arrow on the top of the stem points at 100 fully open position Align the hole on the side of the stem with the tip at the joint surface as a in Fig 7 shows Set the ACTIVAL actuator and valve in 100 position when changing the mounting position If the valve ...

Страница 7: ... direction at which the tip of the valve joint surface with the actuator points when the valve position is fully open See a in Fig 7 Figure 10 Valve stem pointing at 100 fully open position 4 Assemble Model MY53X0A actuator with the valve Engage 4 pins of the actuator with the mating holes on the valve joint surface 5 Move the lock lever to left end to lock Locked position is indicated with the gr...

Страница 8: ...ps halfway valve does not operate at all Conditions of the power applied and of the input signal applied to the actuator Wiring condition disconnected wires of the actuator Foreign substance jammed Check the power supply and the controller connected to Check the wiring Remove foreign substance by manually opening the valve Fluid leaks to the outside of the valve when the assembled actuator fully c...