INSTALLATION INSTRUCTIONS
During installation please observe the instructions according to
GB7000.15 / EN60598-2-17 standards and other national standards
applicable. This luminaire should be installed by a qualified
technician.
The fixture should be used in an environment with a temperature between
-5°C and +45°C. Do not operate the luminaire outside this temperature
range.
The luminaire must be hung so that the weight of this unit multiplied by
10 can be sustained for 1 hour without causing the suspension system or
the supporting structure to be deformed.
The installation must always be secured at a second attach point, e.g., by
a safety cable of the appropriate size.
Do not stand under the luminaire while it is being installed, dismantled or
serviced.
The operator must ensure that a qualified technician has approved the
installation of the luminaire for safety before it is first operated.
Installation should be inspected once a year by a qualified technician.
WARNING!
The installation of this luminaire must be validated by a qualified
technician before it is used for the first time.
The luminaire should be installed in a location where the public cannot,
touch, walk or sit on the luminaire.
Suspending the luminaire and/or installing it high up requires considerable
experience, e.g., calculating load, selecting and adapting quality fastening
materials, and periodically inspecting the entire installation. Without this
skill and knowledge, do not attempt to install this unit by yourself. Improper
installation may cause an accident resulting in personal injury or death.
WARNING!
The luminaire should be connected to an electrical source by a
qualified electrician.
Before installing the luminaire make sure that the selected installation spot
can support at least 10 times the weight of the unit. Connect the luminaire
to the power source by the power cord.
INSTALLATION METHOD USING TRUSS HOOKS
Refer to the following diagram when installing the WILDSUN K25 with
truss hooks using omega bracket:
• Attach the clamp to the omega bracket using an M12 screw.
• Insert the quick-lock fasteners of the first omega bracket into the
respective holes on the base of the unit. Turn the quick fasteners fully
clockwise.
• Install the second omega bracket.
• Insert the safety cable through the holes at the bottom of the base and
the truss or a stable attachment point. Insert the end into the hole and
tighten the safety screw.
Note: The last step is very important to ensure that the luminaire does
not fall.
DMX512 CONNECTION
Connect the DMX input (XLR connector) cable of the luminaire to the DMX
output (female XLR connector) of your controller. You can connect multiple
luminaires to this same DMX line in a daisy chain. The DMX cable must
be a shielded twisted pair that is equipped with male and female XLR
connectors.
Refer to the following diagram when connecting the WILDSUN K25
luminaires in a daisy chain:
Address 1 Address 22 Address 43