OPERATING PARAMETERS

 

• Operating positions: on floor or attached to a support (no flag positioning)

 

• Maximum authorized ambient temperature (Ta Max): 45°C (113°F)

 

• Minimum authorized ambient temperature (Ta Min): -10°C (14°F)

 

• Minimum projection distance: 5 m

DIMENSIONS

 

•  Product: 539 mm x 696 mm x 348 mm (L x H x D)

 

• Protective foam: 600 mm x 720 mm x 410 mm (L x H x D)

WEIGHT

 

• Product: 38 kg

 

• Product in packaging with accessories: 55kg

PRODUCT CODE

 

• 013820: WILDSUN K25 AUTOMATED LUMINAIRE

FOAM FOR FLIGHT CASE

WILDSUN K25 is delivered in a carton packed with a dense, protective 
foam surrounding the fixture. This reusable protective shell is intended for 
a flight case that can be custom built for the luminaire.

AYRTON does not offer custom flight cases for the WILDSUN K25. This 
accessory is to be provided by the user.
The main dimensions of the protective shell appear in the following 
diagram:

A

A

488

602

421

R1

5

WARRANTY

The AYRTON WILDSUN K25 fixture is guaranteed against manufacturing 
defects for the duration of one (1) year from the date of purchase.
This warranty does not cover the unit for evidence of physical shock or 
damage caused by abuse or any use not in accordance with the operating 
conditions set forth in the present user manual.

In addition, cosmetic defects caused by the normal wear and tear of the 
unit are not covered under the warranty.

Any modification to the fixture will void the warranty. AYRTON cannot under 
any circumstances be held liable for quality and conformity regarding the 
installation of this product, which is the responsibility of the installer.

Broken glass lenses on the WILDSUN K25, and any damage that could 
arise thereof, are excluded from the warranty. Any possible cosmetic 
defects, provided you report them to your AYRTON dealer upon unpacking 
the device and before use, may be covered by the warranty.

Note:
The manufacturer is not responsible for any errors or omissions that may 
occur in this document. All information contained in this manual is subject 
to change without notice.

Содержание wildsun k25

Страница 1: ...USER MANUAL V 1 ENGLISH VERSION 04 28 2016...

Страница 2: ......

Страница 3: ...tallation method using truss hooks DMX512 connection DMX512 connection with termintion plug The WILDSUN K25 DMX address setting Control Panel WILDSUN K25 control panel menu Option details Master Slave...

Страница 4: ...power cables attached to your WILDSUN K25 have not been damaged due to cuts and splices or crushed in any way Handle these cables with extreme caution while they are connected to a power source Your...

Страница 5: ...making it resistant but not unbreakable Objects made of hard materials such as steel or glass that fall on the unit may cause breakage of the plastic parts or the body AYRTON cannot be held responsibl...

Страница 6: ...iew 348 136 213 476 DESCRIPTION 1 2 3 4 5 6 7 8 9 1112 13 14 15 16 10 1 LED Assembly 2 Display 3 Left button 4 Mode Esc button 5 Down button 6 Enter button 7 Right button 8 Up button 9 Handle 10 Anten...

Страница 7: ...als and periodically inspecting the entire installation Without this skill and knowledge do not attempt to install this unit by yourself Improper installation may cause an accident resulting in person...

Страница 8: ...the third with DMX address 043 21 22 etc CONTROL PANEL MENU OPTIONS A large number of settings are accessible from the fixture s control panel A good working knowledge of it will enhance the fixture s...

Страница 9: ...Enter Then use the left right arrow keys to select Status Finally use the left right arrow keys to select No DMX Mode w w Scroll through the different options using the left right arrows and press Ent...

Страница 10: ...t arrow keys to change the value displayed Press Enter to confirm Flip Display Allows you to rotate the display by 180 This can be highly useful when the fixture is installed with the head facing down...

Страница 11: ...e Mode Esc key w w Use the up down arrow keys to reach the OPTION menu and press Enter Then use the left right arrow keys to access the ResetDefault submenu w w Use the right left arrow keys to select...

Страница 12: ...ft right arrow keys to access the Calibration submenu w w Press Enter once again to access the password 050 and press Enter to confirm w w Use the left right arrow keys to move from one setting to ano...

Страница 13: ...6 includes scenes 12 13 14 15 Auto Program Part 1 is Program 2 Auto Program Part 2 is Program 3 Auto Program Part 3 is Program 6 The 3 groups of SLAVE fixtures run the Auto Program function in the fol...

Страница 14: ...EEPROM 200 219 Internal program 6 secne41 48 of EEPROM 220 239 Internal program 7 secne49 56 of EEPROM 240 255 no function ERROR MESSAGES When you turn on theWILDSUN K25 it will first perform an autom...

Страница 15: ...d in any way or show any trace of corrosion The safety cable should be attached at the appropriate spot Mechanical parts should show no sign of wear The electrical cables should show no sign of wear c...

Страница 16: ...WARRANTY The AYRTON WILDSUN K25 fixture is guaranteed against manufacturing defects for the duration of one 1 year from the date of purchase This warranty does not cover the unit for evidence of phys...

Страница 17: ...USER MANUAL _ 17...

Страница 18: ...www ayrton eu...

Отзывы: