The DREAMPANEL TWIN luminaire has an IP20 protection rating. 
It is intended strictly for indoor use. It must never be partially or fully 
submerged, even temporarily.

Condensation may form on your DREAMPANEL TWIN in the following 
cases:

 

• Immediately after turning on the heating

 

• In places with fog or a high level of humidity

 

• When the luminaire is suddenly moved from a cold to a warm 

environment, or vice versa.

In such cases, you must wait until the luminaire readjusts to the ambient 
temperature of the room where it will be installed for operation.

Do not shake the DREAMPANEL TWIN while installing or handling.

Do not pull the DREAMPANEL TWIN by one of its cables to move it. Lift the 
luminaire by its handles.

Choosing the appropriate place to install the DREAMPANEL TWIN is 
essential. The following points should be observed:

 

• Do not expose it to a heat source.

 

• Do not install it near flammable materials.

 

• Be sure that dust or miscellaneous debris cannot clump around the 

body of the luminaire as this may interfere with its optimal cooling and 
proper operation.

 

• The DREAMPANEL TWIN must be installed out of reach of the public 

and all persons not authorized to operate the luminaire.

We recommend a minimum distance of 20 cm between the outside 
surface of the light and the illuminated object. The color mixture of the 
DREAMPANEL TWIN can be improved if the illuminated surface is very 
close to the luminaire (up to about 50 cm).

Due to the nature of its cooling principle, you should never prevent air 
from circulating around the body of the luminaire. You must provide a 
minimum clearance of 20 cm around your DREAMPANEL TWIN to allow 
for cooling.

The DREAMPANEL TWIN can be installed in a ground pit or any other 
confined enclosure only under certain conditions. With this kind of 
installation, a system of forced ventilation should be used up to allow 
air to circulate freely around the luminaire(s). The air must be constantly 
renewed because the luminaire cannot be operated in closed system. 
Failure to comply with these requirements may destroy or prematurely 
wear the DREAMPANEL TWIN, and AYRTON cannot be held responsible. 
Please consult your AYRTON dealer for more information on this type of 
installation.

No load should be placed on the DREAMPANEL TWIN. The fixture must 
not be installed in such a way as to allow a person, vehicle or any object 
to run over or park on it.

Never lay or drop any hard, heavy, or blunt, objects on the DREAMPANEL 
TWIN. This includes items made of glass or porcelain (e.g., bottles, 
dishware, or glass beads). The luminaire is made of materials such as 
plastic and extruded aluminum, making it resistant but not unbreakable. 
Objects made of hard materials such as steel or glass that fall on the unit 
may cause breakage of the plastic parts or the body. AYRTON cannot be 
held responsible for the luminaire’s broken plastic parts or body, which are 
not covered under warranty.

The temperature of the room where the DREAMPANEL TWIN is installed 
must never exceed 45°C (Ta = 45°C).

The DREAMPANEL TWIN luminaire requires a 110-240 VAC supply 
voltage. Check that your luminaires have been installed for an application 
that is compatible with this information.

Check that the brackets on which you hang or attach your DREAMPANEL 
TWIN can sustain the weight of the luminaire (25kg), taking into 
consideration all necessary safety factors.

Do not use your DREAMPANEL TWIN before being familiar with these 
recommendations and do not allow unqualified personnel to handle the 
product.

To transport your DREAMPANEL TWIN, we strongly recommend that you 
use the complete original packaging, including the dense protective foam 
inserts.

If your DREAMPANEL TWIN is not being used for a long period, you should 
disconnect the luminaire from the power source.

Never dispose of the DREAMPANEL TWIN in a rubbish bin. Ensure that 
it is recycled. Please consult the current legislation in your country on 
recycling electronic equipment.

WARNING!

The number of daisy chain, or tandem, connections to the 

DREAMPANEL TWIN (power input and output sockets on the 

luminaires) is limited for safety reasons. The maximum authorized 

number of connections is as follows, with the power line protected 

by a 10A circuit breaker:

• 2 DREAMPANEL TWIN units on the same source at 230 VAC 

or

• 1 DREAMPANEL TWIN units on the same source at 110 VAC.

PRESENTATION AND FEATURES

DREAMPANEL TWIN is a non-waterproof moving head wash light (IP20 
protection rating) using the latest generation of high-performance of LED-
type lamps.

This luminaire can be controlled remotely by an external DMX512 signal.

The DREAMPANEL TWIN incorporates multi-chip LEDs using 4 colors: 
Red, green, blue and white.
This color-light luminaire operates on the CMY additive color principle and 
along with white light can potentially render a palette of 4.2 billion colors.

The DREAMPANEL TWIN has a total of 64 LEDs that can be controlled 
independently. The luminaire requires from 18 to 272 DMX channels to be 
controlled via an external command system that sends a DMX512 signal 
(see below for details).

To adjust the settings on the DREAMPANEL TWIN (i.e., DMX address, 
DMX operating mode and other options), a Remote Device Management 

Содержание DREAMPANEL TWIN

Страница 1: ...USER MANUAL V 1 ENGLISH VERSION 12 22 2015 ...

Страница 2: ......

Страница 3: ... instructions Installation method using truss hooks Artnet connection The DreamPanel Twin DMX address setting Control Panel DreamPanel Twin control panel menu option details Master Slave Mode settings Led mapping DMX Chart Error Messages Care and maintenance Technical Specifications Warranty 4 4 4 5 6 7 7 8 8 8 8 9 12 13 14 16 16 17 18 ...

Страница 4: ...lation complies with current standards In all cases make sure that the power cables attached to your DREAMPANEL TWIN have not been damaged due to cuts and splices or crushed in any way Handle these cables with extreme caution while they are connected to a power source Your DREAMPANEL TWIN conforms to Class 1 safety standards The unit must be grounded electrically Make sure that the power source co...

Страница 5: ...de of glass or porcelain e g bottles dishware or glass beads The luminaire is made of materials such as plastic and extruded aluminum making it resistant but not unbreakable Objects made of hard materials such as steel or glass that fall on the unit may cause breakage of the plastic parts or the body AYRTON cannot be held responsible for the luminaire s broken plastic parts or body which are not c...

Страница 6: ...red The RDM protocol is a universal widely used standard The DREAMPANEL TWIN consists of a metal frame and plastic covers The power connectors video and network signal connectors are on the back of the fixture s base DIMENSIONS Bottom view Front view Side view ...

Страница 7: ... of the appropriate size Do not stand under the luminaire while it is being installed dismantled or serviced The operator must ensure that a qualified technician has approved the installation of the luminaire for safety before it is first operated Installation should be inspected once a year by a qualified technician WARNING The installation of this luminaire must be validated by a qualified techn...

Страница 8: ...the one recorded on the DMX controller to run the luminaire This address is the DMX value that appears on the luminaire s display You can set the same address for all the luminaires or some of them but you can also set a different address for each luminaire as needed If you do set the same address for all the luminaires they will all listen from the DMX channel you have set The instructions sent b...

Страница 9: ...am in loop Save and exit Edit Scenes Edit Scene 001 Edit Scene 250 Pan Tilt Fade Time Secne Time Input By Outside Save and automatically return manual scenes edit Scenes Input XX XX Automat scenes rec DREAMPANEL TWIN CONTROL PANEL MENU OPTION DETAILS The following section provides details on the options that can be selected through the control panel menu Refer to the table above Note You can exit ...

Страница 10: ...t Spd w w Scroll through the different options using the left right arrows and press Enter to confirm SERVICE PIN WARNING For normal operation the Service pin menu information should not be changed Contact your dealer for more information Service PIN Allows you to enter a password to access the advanced options such as RDM PID Set IP Set Device IP Set LED BIN and Change to bin pwd 50 w w Access th...

Страница 11: ...arrow keys to select DMX value Disp w w Use the left right arrow keys to select which setting to display Press Enter to confirm Set To Slave Sets the fixture to SLAVE Mode for receiving instructions from a master luminaire see Master Save mode settings below w w Access the menu by pressing the Mode Esc key w w Use the up down arrow keys to reach the OPTION menu and press Enter Then use the left ri...

Страница 12: ...N TILT w w Access the menu by pressing the Mode Esc key w w Use the up down arrow keys to reach the TEST menu and press Enter Then use the left right arrow keys to access the Test Channel submenu w w The fixture then runs in test position Use the left right arrow keys to scroll through and test each setting MANUAL CTRL Allows you to access all the fixture s settings manually e g PAN TILT The shutt...

Страница 13: ... confirm Press MODE ESC to return to the main menu 4 Program selection for Edit Program Use the buttons to select Edit program Press ENTER to confirm Use the buttons to select Edit program Press ENTER to confirm Use the buttons to select the desired program You can edit specific scenes in a given program Press ENTER to confirm Press MODE ESC to return to the main menu 5 Automatic Scene Recording U...

Страница 14: ...LED array 1 0 255 White 0 Black 255 100 White L5 Red LED array 2 0 255 Red 0 Black 255 100 Red L6 Green LED array 2 0 255 Green 0 Black 255 100 Green L7 Blue LED array 2 0 255 Blue 0 Black 255 100 Blue L8 White LED array 2 0 255 White 0 Black 255 100 White L253 Red LED array 64 0 255 Red 0 Black 255 100 Red DMX channel s functions and their values 272 DMX channels Mode Channel Value Function L254 ...

Страница 15: ...4 105 Chase 48 106 107 Chase 49 108 109 Chase 50 110 111 Chase 51 DMX channel s functions and their values 272 DMX channels Mode Channel Value Function St Ba Ex A16 A14 A12 112 113 Chase 52 114 115 Chase 53 116 117 Chase 54 118 119 Chase 55 120 121 Chase 56 122 123 Chase 57 124 125 Chase 58 126 127 Chase 59 128 129 Chase 60 130 131 Chase 61 132 133 Chase 62 134 135 Chase 63 136 137 Chase 64 138 13...

Страница 16: ... sensor or magnet missing or the stepping motor is defective also caused by its driving IC on the main PCB The PAN movement does not return to the default position after the reset CARE AND MAINTENANCE The care and maintenance of your DREAMPANEL TWIN should be ensured by a qualified technician Your DREAMPANEL TWIN requires regular servicing The frequency depends essentially on its operating conditi...

Страница 17: ...utomatic features for managing your luminaire without a DMX console DMX RDM compatible Integrated control panel with LCD display and 6 buttons Ethercon RJ45 input output HDMI input output connector Choice of 3 DMX modes from 18 to 272 channels POWER SUPPLY Electronic power distribution with Power Factor Correction PFC from 110 240 VAC 50 60 Hz 900 Watt maximum power Power supply via powerCON TRUE1...

Страница 18: ...the warranty Any modification to the fixture will void the warranty AYRTON cannot under any circumstances be held liable for quality and conformity regarding the installation of this product which is the responsibility of the installer Broken glass lenses on the DREAMPANEL TWIN and any damage that could arise thereof are excluded from the warranty Any possible cosmetic defects provided you report ...

Страница 19: ...www ayrton eu ...

Отзывы: