DMX channel´s functions and their values (272 DMX channels)
Mode/Channel
Value
Function
St
Ba
Ex
A16
A14
A12
222-223
Chase 107
224-225
Chase 108
226-227
Chase 109
228-229
Chase 110
230-231
Chase 111
232-233
Chase 112
234-235
Chase 113
236-235
Reserved
A17
A15
A13
Chase Speed:
0-125
Fast to Slow Backward
126-130
Stop(Speed=0)
131-255
Slow to Fast Forward
A18
A16
A14
Chase Fade:
0-255
Fade Chase
A20
A18
A16
Reset, internal programs:
0-79
Normal
80-84
All motor reset
85-87
Scan motor reset
88-90
no function
91-93
no function
94-96
no function
97-99
no function
100-119
Internal program 1 (secne1~8 of EEPROM)
120-139
Internal program 2 (secne9~16 of EEPROM)
140-159
Internal program 3 (secne17~24 of EEPROM)
160-179
Internal program 4 (secne25~32 of EEPROM)
180-199
Internal program 5 (secne33~40 of EEPROM)
200-219
Internal program 6 (secne41~48 of EEPROM)
220-239
Internal program 7 (secne49~56 of EEPROM)
240-255
Internal program 8 (secne57~64 of EEPROM)
ERROR MESSAGES
When you turn on the DREAMPANEL TWIN, it will first perform an
automatic reset. The display may show “Err channel is XX” indicating there
is a problem with one or more of the channels. “XX” represents channel
1, 2, 3, 4, 5 or 6, which contain the testing sensor for positioning. For
example, the message, “Err channel is Red LED -all arrays”, indicates an
error in channel 1. If there is an error on channel 1 and channel 3 at the
same time, the following error message may appear: “Err channel is Pan
movement”, “Err channel is Tilt movement”. The system will flash twice,
and the fixture will generate a second reset. If the error message persists
after more than two resets, the channels showing errors will not work
properly but the other channels will function normally.
Please contact your authorized dealer or manufacturer for service and do
not attempt to repair the luminaire yourself.
PAN- MOVEMENT ER
(PAN-yoke movement error): This message will appear after the reset
if the yoke’s magnetic-indexing circuit malfunctions (failed sensor or
magnet missing) or the stepping-motor is defective (also caused by its
driving IC on the main PCB). The PAN- movement does not return to the
default position after the reset.
CARE AND MAINTENANCE
The care and maintenance of your DREAMPANEL TWIN should be ensured
by a qualified technician. Your DREAMPANEL TWIN requires regular
servicing. The frequency depends essentially on its operating conditions
and environment. Intensive use in a dusty environment, or a lack of
ventilation around the fixture, may disrupt operation, result in overheating
and cause damage that is not covered by the warranty.
WARNING!
Disconnect from mains before servicing.
UPDATING THE LUMINAIRE
Ayrton is continually upgrading this product line. It is therefore possible
that a new software version is available that will increase the unit’s
capabilities.
Updates are performed using Ayrton’s update box. Contact your dealer for
more information.
To display the version of your device, go into the “Info” menu and select
“Software version” (see options details under the “INFO” menu). It is
advisable to use the same software version for multiple fixtures.
CLEANING
Your DREAMPANEL TWIN requires cleaning at regular intervals. Be aware
that accumulated dust and residue on the air vents, body and glass of the
fixture may reduce efficiency and impair proper operation.
Before cleaning, disconnect the power cable from source.
Use compressed air to blow away dust particles accumulated on and
between the cooling fins at the rear of the luminaire’s optical system.
Clean the glass of the fixture with a slightly damp soft cloth. When
necessary, use a non-alcohol-based glass cleaner. Never use harsh
solvents!
WARNING!
Never use alcohol or any chemical agent to clean the optical system
of an Ayrton product.
COMPLIANCE CHECK
• Your installation should be checked regularly by certified service center.
• In addition, the following should be checked once a year by a qualified
technician:
• The fixture’s attachment system must be correctly installed and show
no sign of corrosion.
• The fixture’s mounting bracket should not be distorted in any way or
show any trace of corrosion.
• The safety cable should be attached at the appropriate spot.