AIR FILTER MAINTENANCE
It is necessary to clean the air filter after using it for about 100 hours. Clean as follows:
• Stop the appliance and remove the air filter.
• Clean and reinstall the air filter.
• If the dirt is conspicuous, wash it with a solution of detergent in lukewarm water. After
cleaning, dry in the shades and cool place, then reinstall it.
• Clean the air filter every two weeks if the air conditioner operates in an extremely dusty
environment.
MAINTENANCE AFTER USING
• If the appliance will not be used for a long time, be sure to pull out the primary and the
secondary rubber plug of the drain port, in order to drain the water.
• Keeps the appliance running with fan only for a half day during a sunny day to dry the
appliance inside and prevent from going moldy.
• Stop the appliance and pull out the power supply plug, then take out the batteries of
remote controller and store appliance properly.
• Clean the air filter and reinstall it.
• Remove air hoses and store them properly, and cover the hole tightly.
TECHNICAL SPECIFICATIONS
Model
YGP35-1170ZP
Cooling Capacity (Btu/h)/ W
12.000 Btu/h / 3500 W
Dehumidifying Capacity (l/h)
1.9 l/h
Standard Cooling Input Power/Current
1300 W/5,8A
Air Flow Volume (m³/h)
350 m³/h
Rated Voltage /Frequency (V/Hz)
220-240 V~/50 Hz
Sound Pressure Level (dB (A))
LPA
≤
55dB (A)
LWA
≤
65 dB (A)
2,6
Global Warming Potential (kg CO2)
2100
EER Class
A
Net Weight (Kg)
30 kg
Dimensions W X D X H
386 x 390 x 806 mm
Refrigerant
R410A
Applying Space (m²)
20 m²
Miniature Fuse
3,15 A / 250 V ø5 x L 20 mm