TECHNICAL AND MOTION DOCUMENTATION
___________________________________________________________________________________________________
12
Tags numbers and wires colours:
Tag no.
Signal
Wire colour
External keys inputs:
11
F1
green
12
F2
white
13
F3
brown
14
F4
yellow
15
F5
red
20
+24V (external PSU voltage)
black
External keys connection method:
+24V
0V
F1
F2
F1(11)
F2(12)
+24V(20)
Waga
Obiekt
8. General operation principles
1.
Platform with weight sensors should be located on flat, horizontal foundation, in place
not subjected to mechanical vibrations and strong air movements.
2.
Devices turning on sequence: turn on computer, software, balance meter power supply.
It causes autotests performing and (after balance stabilization) displaying zero
indication.
3.
Apart from connecting to the computer, the module allows for weighing and tare setting.
Tare setting is performed by pressing "T/
ON
" key. If the package tare is entered with
alphanumeric keyboard, using "T/
ON
" key is not necessary.
4.
To facilitate the weight control on the pan and avoid the range exceeding, the load
indicator is located on the right side of display, scaled in 0÷100%.
5.
The weighing result should be read during the " " indicator lighting, which indicates the
result stabilization.