AXIS Q6054-E PTZ Dome Network Camera
Events
-
Live Stream Accessed
– Trigger the rule when any stream is accessed and during edge storage playback.
This can for example be used to send notifications.
-
Motion Detection
– Trigger the rule when motion is detected. See
.
-
Shock Detection
– Trigger the rule when the Axis product detects it has been tilted or hit. See
.
•
Hardware
-
Casing Open
– Triggers the rule if the casing of a connected external device, such as a junction box or cabinet
(not included), is removed or opened. This can for example be used to send notifications of maintenance or
unauthorized tampering.
-
Fan
– Trigger the rule if the fan is malfunctioning. This can for example be used to send maintenance
notifications.
-
Heater
– Trigger the rule if the heater is malfunctioning. This can for example be used to send maintenance
notifications.
-
Network
– Trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
-
Temperature
– Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example be used to send maintenance notifications.
•
Input Signal
-
Manual Trigger
– Trigger the rule using the
Manual Trigger
button in the Live View page. See
. This can for example be used to validate actions during product installation
and configuration.
-
Virtual Inputs
– can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, be connected to buttons in the VMS user interface.
•
PTZ
-
Autotracking
– Trigger the rule when autotracking starts or stops. See
.
-
Error
– Trigger the rule if the PTZ functionality is not working correctly. This can for example be used to
send maintenance notifications.
-
Moving
– Trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motion detection to record video while the
camera view moves due to a PTZ operation.
-
Preset Reached
– Trigger the rule when the camera stops at a preset position. This can be for example be used
with the Send Images action to upload images from the preset position.
-
Ready
– Trigger the rule when the PTZ functionality is ready to be used. This can for example be used to steer
the camera to a specific preset position when the product is started.
•
Storage
-
Disruption
– Trigger the rule if storage problems are detected, for example if the storage device is unavailable,
removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance
notifications.
-
Recording
– Triggers the rule when the Axis product records to the storage device. The recording status trigger
can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to
record to the storage device. Note that, this trigger can be used only for edge storage recording status.
•
System