background image

A3090-1.1 en

5

Network Camera Devices

  Safety Information

Safety Rules

The supply connection, as well as the signal and sense leads, must be installed in 
such a way that electromagnetic interference does not adversely affect device 
functionality.
Automation equipment and devices must be covered over in such a way that adequate 
protection or locking against unintentional actuation is provided (such as access 
checks, password protection, etc.).
When devices are working in a network, these networks must be designed in such a 
way that malfunctions in individual nodes can be detected and shut down.
Safety precautions must be taken both in terms of hardware and software, so that a 
line break or other interruptions to signal transmission, such as via the bus interfaces, 
do not cause undefined states or loss of data in the automation device.
Before connecting the device, make sure that the mains voltage and current type 
specified on the type plate correspond to the mains voltage and current type at the site 
of installation and that the current circuit used is sufficiently safe.
The maximum permissible supply voltage for Axis network camera devices is 
20 V DC.

Appropriate use

The Axis network camera devices and their connected transducers may be used for 
measurement tasks only and directly related control tasks. To ensure safe operation, 
the transducer may only be used as specified in the operating manual. It is also 
essential to follow the respective legal and safety regulations for the application 
concerned during use. The same applies to the use of accessories.
Each time, before starting up the equipment, you must first run a project planning and 
risk analysis that takes into account all the safety aspects of automation technology. 
This particularly concerns personal and machine protection.
Additional safety precautions must be taken in plants where malfunctions could cause 
major damage, loss of data or even personal injury. In the event of a fault, these 
precautions establish safe operating conditions.
This can be done, for example, by mechanical interlocking, error signaling, limit value 
switches, etc.

General dangers of failing to follow the safety instructions

The Axis network camera devices comply with the state of the art and are safe to 
operate. Inappropriate use and operation by untrained personnel can give rise to 
remaining dangers.
Anyone responsible for installing, starting up, maintaining or repairing the equipment 
needs to have read and understood the operating manual and in particular the safety 
instructions. 

Содержание Axis 211

Страница 1: ...Quick Start Guide English Deutsch Espanol A3090 1 1 en SoMat P N SO DOC 0102 Network Camera Devices SoMat eDAQ eDAQlite...

Страница 2: ...Network Camera Devices 2 A3090 1 1 en...

Страница 3: ...k Camera 9 1 2 1 Reset the Camera to Factory Default 9 1 2 2 Configure the Camera 10 1 3 Step 2 Configure and Run a Test 11 1 3 1 Add a Camera Message Channel 11 1 4 Step 3 View the Camera Data 12 2 T...

Страница 4: ...Network Camera Devices 4 A3090 1 1 en...

Страница 5: ...te use The Axis network camera devices and their connected transducers may be used for measurement tasks only and directly related control tasks To ensure safe operation the transducer may only be use...

Страница 6: ...g dangers connected with measurement technology After making settings and carrying out activities that are password protected you must make sure that any controls that may be connected remain in safe...

Страница 7: ...ed When exchanging complete assemblies it is essential to use original HBM parts only The product is delivered from the factory with a fixed hardware and software configuration Changes can only be mad...

Страница 8: ...Network Camera Devices 8 A3090 1 1 en...

Страница 9: ...ded Test Control Environment TCE see previous section for compatible versions InField version 2 4 0 or later 1 2 Step 1 Set Up the Network Camera 1 2 1 Reset the Camera to Factory Default First reset...

Страница 10: ...bleshooting steps in Troubleshooting During Configuration on page 15 6 Click on the Correct camera configuration link under the camera entry to open the camera configuration page Follow the on screen...

Страница 11: ...a Test 1 3 1 Add a Camera Message Channel To record camera data configure a TCE test with a camera message channel 1 Start TCE 3 14 or later and either open an existing test or create a new test Make...

Страница 12: ...ports multiple input channels and triggering options 10 To be able to view camera data later in InField it is necessary to create a channel with time information and add it to a Time History DataMode...

Страница 13: ...ing through the camera frames The timestamp of the image is indicated by the x value on the multiplot The timestamp is test run time To calculate real time view the test start time in the metadata vie...

Страница 14: ...Network Camera Devices 14 A3090 1 1 en...

Страница 15: ...gured camera 1 Ping the camera s IP address to confirm that the eDAQlite can communicate with the camera To ping the camera navigate to the system tab on the web interface and click Command Prompt In...

Страница 16: ...liability whatsoever measure and predict with confidence The Americas HBM Inc 19 Bartlett Street Marlboro MA 01752 USA Tel 1 800 578 4260 Email info usa hbm com Europe Middle East and Africa HBM GmbH...

Отзывы: