background image

A3090-1.1 en

15

Network Camera Devices

2 Troubleshooting

Most of the issues that can cause the camera to not function properly are network 
related. Try the following to troubleshoot any camera issues.

2.1

Troubleshooting During Configuration

To troubleshoot during camera configuration:

Repeat the camera configuration steps outlined in 

“Configure the Camera” on 

page 10

.

Power cycle any switches or routers on the network.

If camera cannot be found on the network, try entering the camera serial 
number in the Configure Networked Camera section of the eDAQ web interface 
to search for the specified camera.

Reset the camera to its factory default as outlined in 

“Reset the Camera to 

Factory Default” on page 9

 and repeat the camera configuration.

If the problem persists:

Consult with the local IT department to resolve any network issues.

Contact HBM technical service. Please carefully record all troubleshooting 
results before contacting HBM.

2.2

Troubleshooting After Configuration

To troubleshoot a previously configured camera:
1. Ping the camera’s IP address to confirm that the eDAQ

lite

 can communicate with 

the camera. To ping the camera, navigate to the system tab on the web interface 
and click Command Prompt. In the command prompt, type “ping xxx.xxx.xxx.xxx”, 
where the x’s are the IP address for the camera.

2. If there is no reply, check all the network connections including Ethernet cables, 

routers and switches. Make sure the network LEDs on the camera and the POE 
switch are active.

3. If there is a ping reply but the problem remains, reset the camera to its factory 

default as outlined in 

“Reset the Camera to Factory Default” on page 9

 and repeat 

the camera configuration.

If the problem persists:

Consult with the local IT department to resolve any network issues.

Contact HBM technical service. Please carefully record all troubleshooting 
results before contacting HBM.

2.3

Configured Axis M7001 Does Not Show Video

When using the Axis M7001, make sure to close all like video feeds before recording 
data. Because of resolution restrictions, the M7001 cannot deliver video for recording 
or as a thumbnail and as a live, full-resolution feed (opened by clicking the thumbnail 
in the hardware specifics column of the web interface).

Содержание Axis 211

Страница 1: ...Quick Start Guide English Deutsch Espanol A3090 1 1 en SoMat P N SO DOC 0102 Network Camera Devices SoMat eDAQ eDAQlite...

Страница 2: ...Network Camera Devices 2 A3090 1 1 en...

Страница 3: ...k Camera 9 1 2 1 Reset the Camera to Factory Default 9 1 2 2 Configure the Camera 10 1 3 Step 2 Configure and Run a Test 11 1 3 1 Add a Camera Message Channel 11 1 4 Step 3 View the Camera Data 12 2 T...

Страница 4: ...Network Camera Devices 4 A3090 1 1 en...

Страница 5: ...te use The Axis network camera devices and their connected transducers may be used for measurement tasks only and directly related control tasks To ensure safe operation the transducer may only be use...

Страница 6: ...g dangers connected with measurement technology After making settings and carrying out activities that are password protected you must make sure that any controls that may be connected remain in safe...

Страница 7: ...ed When exchanging complete assemblies it is essential to use original HBM parts only The product is delivered from the factory with a fixed hardware and software configuration Changes can only be mad...

Страница 8: ...Network Camera Devices 8 A3090 1 1 en...

Страница 9: ...ded Test Control Environment TCE see previous section for compatible versions InField version 2 4 0 or later 1 2 Step 1 Set Up the Network Camera 1 2 1 Reset the Camera to Factory Default First reset...

Страница 10: ...bleshooting steps in Troubleshooting During Configuration on page 15 6 Click on the Correct camera configuration link under the camera entry to open the camera configuration page Follow the on screen...

Страница 11: ...a Test 1 3 1 Add a Camera Message Channel To record camera data configure a TCE test with a camera message channel 1 Start TCE 3 14 or later and either open an existing test or create a new test Make...

Страница 12: ...ports multiple input channels and triggering options 10 To be able to view camera data later in InField it is necessary to create a channel with time information and add it to a Time History DataMode...

Страница 13: ...ing through the camera frames The timestamp of the image is indicated by the x value on the multiplot The timestamp is test run time To calculate real time view the test start time in the metadata vie...

Страница 14: ...Network Camera Devices 14 A3090 1 1 en...

Страница 15: ...gured camera 1 Ping the camera s IP address to confirm that the eDAQlite can communicate with the camera To ping the camera navigate to the system tab on the web interface and click Command Prompt In...

Страница 16: ...liability whatsoever measure and predict with confidence The Americas HBM Inc 19 Bartlett Street Marlboro MA 01752 USA Tel 1 800 578 4260 Email info usa hbm com Europe Middle East and Africa HBM GmbH...

Отзывы: