45
AXIS 242S IV - System options
SNMP
The Simple Network Management Protocol (SNMP) allows the remote management of
network devices. Select the version of SNMP to use, depending on the level of security
required. Select the version of SNMP to use, by checking the appropriate box. The three
levels of security are:
• SNMP V1 - includes no security
• SNMP V2c - uses very simple security, e.g. community name as password
• SNMP V3 - provides encryption and secure passwords. Use with HTTPS.
If using V1 and V2c, enter the community name for read-only access to all supported
SNMP objects (except the root password and other objects that require write access).
Default value = public. You can also specify the community name for read/write access to
all supported SNMP objects (except read-only objects). Default value = pass.
If using HTTPS, enter the password if it has not already been set. To set the password
again, the AXIS 242S IV must be reset to the factory default settings.
UPnP™
The video server includes support for UPnP
™
in Windows ME and Windows XP. UPnP
™
is
enabled by default.
Note:
UPnP™ must be installed on your workstation if running Windows XP. To do this, open the Control Panel
from the
Start Menu
and select
Add/Remove Programs
. Select
Add/Remove Windows Components
and
open the
Networking Services
section. Click
Details
and then select
UPnP
™ as the service to add.
RTP (Multicast)/MPEG-4
These settings are the IP address, port number, and Time-To-Live value to use for the
media stream(s) in multicast MPEG-4 format. Only certain IP addresses and port numbers
should be used for multicast streams. For more information, please see the online help.
Ports & devices
I/O Ports
- the pinout, interface support and the control and monitoring functions
provided by this connector are described in
Unit connectors
, on page 49.
RS232
- The COM port RS-232 on the AXIS 242S IV supports several operational modes
listed on this page. For more information, please see
COM ports RS-232 and RS-485,
on
page 51.
RS485
- The COM ports on the AXIS 242S IV supports several operational modes listed on
this page. For more information, please see
COM ports RS-232 and RS-485,
on page 51.