32
AXIS 242S IV - Event configuration
7. Click
Save
.
Please use the online help
for descriptions of each available option.
High
Only very large objects
trigger motion detection
An object that appears in the region will
trigger the motion detection for a long
period
Ordinary colored objects against ordinary
backgrounds will trigger the motion
detection
Low
Even very small objects
trigger motion detection
An object that appears in the region will
trigger motion detection for only a very
short period
Only very bright objects against a dark
background will trigger motion detection
Default values Low
Medium to High
Medium to High
Examples:
• Avoid triggering on small objects in the image by selecting a high
size
level.
• To trigger motion detection as long as there is activity in the area, select a high
history
level.
• To only detect flashing light, low
sensitivity
can be selected. In other cases, a high
sensitivity
level is
recommended.
Port status
Under
Event Configuration > Port Status
, there is a list that shows the status for the
connected inputs and outputs of the AXIS 242S IV. This is for the benefit of an operator,
who cannot access the System Options section.
Example:
If the Normal state for a push button connected to an input is set to Open circuit, as long as the button is
not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.
If there are parts of the Include window that you wish to exclude, click the
Configure Excluded Windows
radio button and perform steps 1-6 above.