background image

 

 

 

 

IV. ELECTRONIC SYMBOLS  

 

WARNING! 

 

DC 

 

HIGH VOLTAGE ! 

 

AC 

 

GND 

 

DC & AC 

 

DUAL INSULATION 

 

 

CONFORMITE 
EUROPEENNE 

 

LOW BATTERY 

 

FUSE 

 

V.GENERAL SPECIFICATION  

The maximum voltage is 500V rms between the voltage input terminal and ground . 
10A terminal : without fuse . 
MA terminal fuse : 

φ

5×20mm 200mA/250V 

Range selector : manual  
Backlight function : manual put on & off  
Maximum display : 1999, update 2~3 times per second. 
Polarity display : negative polarity input display . 
Over range display : 1 . 
Data hold function : left bottom of  LCD displays H . 

Low battery: LCD displays 

 

symbol. 

Built-in battery : 9V NEDA1604 /6F22 /006P. 
Operation temperature: 0°  ~40°  ( 32° ~104°  ) 

Storage temperature: - 10°

 ~50

°

 (14

°

 ~122

°

 ) 

Dimensions : 150mm ×73.5mm × 35mm. 
Gross weight: Approx:156g(include battery) 
PANEL DESCRIPTION (FIG.1) 

1.

 

LCD  Display 

2.

 

Data hold key  

3.

 

Backlight key  

4.

 

Range switch  

5.

 

GND input end  

6.

 

10A current input terminal 

7.

 

Other measurement input end   

VI.PANEL DESCRIPTION  

1.

 

Data hold display  :    Press  the  yellow  colored  “HOLD”  key  ,LCD  display  presents  measured  value  . 

Press it again to exit the data hold function . 
2.

 

Backlight control : Press the yellow colored “B/L” key to turn on the backlight ,press it again to turn 

Содержание AX-101B

Страница 1: ...DIGITAL MULTIMETER AX 101B OPERATION MANUAL...

Страница 2: ...e weakened or lost 1 Before operation ensure that the insulation layer of test leads remains unwounded Do not operate the meter if test leads cable or housing insulation is obviously damaged 2 When op...

Страница 3: ...function left bottom of LCD displays H Low battery LCD displays symbol Built in battery 9V NEDA1604 6F22 006P Operation temperature 0 40 32 104 Storage temperature 10 50 14 122 Dimensions 150mm 73 5mm...

Страница 4: ...est range then select a proper range according to the displaying value If LCD displays 1 it means over range set the knob to a higher range On each range the input impedance of instrument is 10M such...

Страница 5: ...rminal 4 2 Set the fuction range knob to resistance range multipled the test leads to the resistance under tested 4 3 Read the measured value from the LCD NOTE To avoid the damage of the instrument be...

Страница 6: ...is 6 SQUARE WAVE SIGNAL OUTPUT Set the knob to square wave range the instrument output square wave between V mA and COM NOTE Square wave experiment signal with its rich harmonics can be used as a sim...

Страница 7: ...protection 500 V DC or AC peak value Frequency response 40 400 Hz Display sine wave RMS 3 DCA RANGE ACCURACY RESOLUTION 2mA 1 0 2 1 A 20mA 10 A 200mA 1 2 2 100 A 10A 2 0 5 10mA Max input current 10A l...

Страница 8: ...m circuit under tested and input jack Set the knob to off gears and turn off the power 2 Loosen the screws on battery case by screwdriver and remove the battery case 3 Take out the old battery and rep...

Отзывы: