UMAX140900. Ethernet to CAN Converter. Version 5
Page: 30-35
Use mating A-coded connectors compliant with IEC 61076-2-101:2012.
The AX070532 CAN Cable - 1.5 m (5 ft.), 5-pin M12 A-coded, Unterminated Leads, can be
used for experimenting. The cable is rated -
40…+105 °C.
8.4 General Specifications
Table 10. General Specifications
Parameter
Value
Remarks
Operating Temperature
-
40…+85 °C
Industrial temperature range
Storage Temperature
-
40…+85 °C
Environmental Protection
IP67
IEC 60529
Vibration
Sine sweep, 5-200 Hz, 8.9G peak, 2.5
hr (15 sweeps), each axis.
Random, 10-1014 Hz, 6.86 Grms, 5.0
hr, each axis.
Custom profile
Shock
50G peak, 5 shocks, each axis
Custom profile
Size
4.19in x1.82in x1.32in
(107mm x 47mm x 34 mm)
See dimensional drawing
Weight
0.15 lb (0.068 kg)
Compliance
RoHS Directive
Table 11. Electromagnetic Compatibility (EMC)
Standard
Description
DIN EN 13309:2010
and ISO13766-1:2018
Construction Machinery- Electromagnetic Compatibility of Machines with
Internal Electrical Power Supply.
Earth-moving and building construction machinery
— Electromagnetic
compatibility (EMC) of machines with internal electrical power supply
— Part
1: General EMC requirements under typical electromagnetic environmental
conditions
EN61000-6-4:2005
Emission Standard for Industrial Environments
EN61000-6-2:2007
Generic Standards
– Immunity for Industrial Environments
8.5 Accessories
Table 12. Accessories
Axiomatic P/N
Description
AX140910
Software Support Package (SSP). Downloadable from
, log-in
section.
AX070531
AX070531 Ethernet and Power Cable - 1.7m (5.5 ft.), 8-pin M12 A-coded,
Unterminated Leads, Ethernet Jack.
AX070532
CAN Cable - 1.5 m (5 ft.), 5-pin M12 A-coded, Unterminated Leads.
AX140900K
Service tool kit, contains:
•
AX140900 Ethernet-CAN Converter;
•
AX070531 Ethernet and Power Cable - 1.7m (5.5 ft.), 8-pin M12 A-coded,
Unterminated Leads, Ethernet Jack;
•
AX070532 CAN Cable - 1.5 m (5 ft.), 5-pin M12 A-coded, Unterminated Leads.