administrator the same way as with the server configuration. After that, the user should set the
Device Port Type, Remote IP Address
and
Remote Port
to match the settings of the converter
in the server mode and activate the client mode by setting the
Auto Connect to Remote
to
Yes
.
The CAN network setup is done similarly to the server mode; the
Baud Rate
is set to the
desired baud rate (not necessarily the same as on the server) and the
Loopback Messages
is
set to
No
.
An example of the converter configuration in a client mode is presented in Figure 24.
Figure 24. The Converter Client Configuration Example
The values of the
Device Port Type, Remote IP Address
and
Remote Port
of the client on
Figure 24 are the same as the
Device Port Type
,
Device IP Address
and
Device Port
of the
server in Figure 23.