2.2. Mounting
Instructions
NOTES & WARNINGS
Do not install near high-voltage or high-current devices.
Note the operating temperature range. All field wiring must be suitable for that temperature range.
Install the unit with appropriate space available for servicing and for adequate wire harness access (15
cm) and strain relief (30 cm).
Do not connect or disconnect the unit while the circuit is live, unless the area is known to be non-
hazardous.
MOUNTING
The module is designed for mounting on the valve block. If it is mounted without an enclosure, the controller
should be mounted horizontally with connectors facing left or right, or with the connectors facing down, to
reduce likelihood of moisture entry.
Mask all labels if the unit is to be repainted, so label information remains visible.
Mounting legs include holes sized for ¼” bolts. The bolt length will be determined by the end-user’s mounting
plate thickness. Typically, 20 mm (3/4 inch) is adequate.
If the module is mounted away from the valve block, no wire or cable in the harness should exceed 30 meters
in length. The power input wiring should be limited to 10 meters.
CONNECTIONS
Use the following Deutsch IPD mating plugs to connect to the integral receptacles. Wiring to these mating
plugs must be in accordance with all applicable local codes. Suitable field wiring for the rated voltage and
current must be used. The rating of the connecting cables must be at least 85°C. For ambient temperatures
below –10°C and above +70°C, use field wiring suitable for both minimum and maximum ambient
temperature.
Refer to the respective Deutsch IPD datasheets for usable insulation diameter ranges and other instructions.
Receptacle Contacts
Mating Sockets as appropriate
(Refer to
www.laddinc.com
for more information on the
contacts available for this mating plug.)
Mating Connector
DTM06-12SA, DTM06-12SB, 2 wedges WM12S, 24
contacts (0462-201-20141)