Preliminary User Manual UMAX023241 - Version: 1.1 16-63
Override input allows the output drive to be configured to go to a default value in the case of the
override input being engaged or disengaged, depending on the logic selected in
Override
Response
, presented on Table 11. When active, the output will be driven to the value in
Output at
Override Command
regardless of the value of the Control input. The
Override Source
and
Override Number
together determine the Override input signal.
Table 11: Override Response Options
0 Override When On
1 Override When Off
If a fault is detected in any of the active inputs (Control/Enable/Override) the output will respond per
Control Fault Response
object as outlined in Table 12. Fault Value is defined by
Output in Fault
Mode
object value, which is interpreted in selected output units.
Table 12: Fault Response Options
0 Shutoff Output
1 Apply Fault Value
2 Hold Last Value
1.5.
Miscellaneous Function Block
Figure 8: Miscellaneous objects