UHF Analog Driver/Transmitter/
Chapter 4, Circuit Descriptions
Translator
LX Series, Rev. 3
4-16
4.5 (A4) Control Monitoring/Power
Supply Module (110 VAC, 1301936 OR
220 VAC, 1303229;Appendix B)
The Control Monitoring/Power Supply
Module Assembly contains (A1) a Power
Protection Board (1302837), (A2) a 600
Watt Switching Power Supply, (A3) a
Control Board (1302021), (A4) a Switch
Board (1527-1406) and (A5) a LCD
Display.
AC Input to Innovator LX Exciter/Amplifier
Chassis Assembly
The AC input to the Exciter/Amplifier
Chassis Assembly is connected from J1,
part of a fused entry module, located on
the rear of the chassis assembly to J50
on the Control Monitoring/Power Supply
Module. There are two possible modules
that can be part of your system, 1301936
for 110 VAC or 1303229 for 220 VAC
operation. J50-10 is line #1 input, J50-8
is earth ground and J50-9 is line #2
input. The input AC connects to J1 on
the Power Protection Board where it is
fuse protected and connected back to
J50, at J50-11 AC Line #1 and J50-12 AC
Line #2, for distribution to the cooling
Fan.
4.5.1 (A1) Power Protection Board
(1302837; Appendix B)
The input AC connects through J1 to two
10 Amp AC fuses F1 and F2. The AC
line #1 input connects from J1-1 to the
F1 fuse. The AC line #1 input after the
F1 fuse is split with one line connected
back to Jack J1 Pin 4, which becomes
the AC Line #1 to the Fan. The other
line of the split connects to J4. The AC
line #2 input connects from J1-3 to the
F2 fuse. The AC line #2 input after the
F2 fuse is split with one line connected
back to Jack J1 at Pin 5, which becomes
the AC Line #2 to the Fan. The other
line of the split connects to J2. J1-2 is
the earth ground input for the AC and
connects to J3.
Three 150 VAC, for 115 VAC input, or three
275 VAC, for 230 VAC input, MOVs are
connected to the input AC for protection.
One connects from each AC line to ground
and one connects across the two lines.
VR1 connects from J4 to J2, VR2 connects
from J4 to J3 and VR3 connects from J2 to
J3.
4.5.1.1 +12 VDC Circuits
+12 VDC from the Switching Power
Supply Assembly connects to J6 on the
board. The +12 VDC is divided into four
separate circuits each with a 3 amp self
resetting fuse, PS3, PS4, PS5 and PS6.
The polyswitch resettable fuses may open
on a current as low as 2.43 Amps at
50°C, 3 Amps at 25°C or 3.3 Amps at
0°C. They definitely will open when the
current is 4.86 Amps at 50°C, 6 Amps at
25°C or 6.6 Amps at 0°C.
PS3 protects the +12 VDC 2 Amp circuits
for the System Controller, the Amplifier
Controller and the Spare Slot through J62
pins 7, 8, 9 and 10. If this circuit is
operational, the Green LED DS3, mounted
on the board, will be lit.
PS4 protects the +12 VDC 2 Amp circuits
for the Modulator and the IF Processor
through J62 pins 13, 14, 15 and 16. If
this circuit is operational, the Green LED
DS4, mounted on the board, will be lit
PS5 protects the +12 VDC 2 Amp circuits
for the Upconverter through J62 pins 17,
18, 19 and 20. If this circuit is
operational, the Green LED DS5, mounted
on the board, will be lit
PS6 protects the +12 VDC 2 Amp circuits
for the Remote through J63 pins 17, 18,
19 and 20. If this circuit is operational,
the Green LED DS6, mounted on the
board, will be lit
4.5.1.2 -12 VDC Circuits
-12 VDC from the Switching Power Supply
Assembly connects to J5 on the board.
Содержание INNOVATOR
Страница 99: ...APPENDIX A LX SERIES ANALOG SYSTEM SPECIFICATIONS...
Страница 102: ...APPENDIX B DRAWINGS AND PARTS LISTS...
Страница 105: ...APPENDIX C TRANSMITTER LOG SHEET...