UHF Analog Driver/Transmitter/
Chapter 3, Site Considerations,
Translator
Installation and Setup Procedures
LX Series, Rev. 3
3-13
3.5.4 Front Panel Screens for the
Exciter/Amplifier Chassis Assembly
A 4 x 20 display located on the front of
the Control & Monitoring/Power Supply
Module is used in the LX Series
transmitter for control of the operation
and display of the operating parameters
of the transmitter. Below are the display
screens for the system. The
↑
and
↓
characters are special characters used to
navigate up or down through the menu
screens. Display text flashes on discrete
fault conditions for all screens that
display a fault condition. When the
transmitter is in operate mode, the STB
menu appears. When the transmitter is
in standby mode, the OPR menu
appears.
NOTE:
In systems with two exciters and
an exciter switcher the following screens
appear on the exciter that is selected as
the On Air Exciter.
Display Menu Screens for the LX Series Transmitter/Translator
Table 3-14: Menu 01 - Splash Screen #1
This is the first of the two transmitter splash screens that is shown for the first few
seconds after reset or after pushing the SPL button on the Main Screen. Will
automatically switch to the second splash screen.
Table 3-15: Menu 02- Splash Screen #2
This is the second of the two transmitter splash screens. Will automatically switch to the
Main Screen. The Model Number, Code Version Number and Firmware Number for your
system are displayed on this screen. Make note of these two numbers when conferring
with Axcera on software problems.
Table 3-16: Menu 10 - Main Screen:
This is the default main screen of the transmitter
. When the transmitter is in
operate, the 'STB' characters appear, allowing an operator to place the transmitter in
STANDBY, by pushing the right most button located under to display. When the
transmitter is in standby the 'STB' characters are replaced with 'OPR' and the forward
power values are displayed as OFF. An operator can change the transmitter from
STANDBY to OPERATE by pressing the right most button on the front panel display. If the
transmitter is in operate mode but off due to a modulation fault, the display reports the
system power as Auto Off. Pushing the SPL button will display the two splash screens.
If the
↓
key is activated the display changes to Menu 11, the System Error List Access
Screen. If the
↑
key is activated the display changes to Menu 13, the Transmitter
Configurations Access Screen.