Avtron M6C-4 Скачать руководство пользователя страница 7

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

THIS DOCUMENT CONTAINS 

PROPRIETARY INFORMATION OF 

NIDEC INDUSTRIAL SOLUTIONS 

AND MAY NOT BE DISCLOSED TO 

OTHERS OR USED FOR 

MANUFACTURING PURPOSES 

WITHOUT THE WRITTEN CONSENT

OF NIDEC INDUSTRIAL 

SOLUTIONS.

DRAWN

CHECKED

APP'D

ENG

APP'D

PROD

DATE

CLEVELAND, OH  USA

IMF

PSF

REV

SIZE

CAGE NO.

DWG NO.

SCALE

SHEET

ZIVKOVIC

B38053

0FMV7

1  OF 1 

-

10/4/2019
10/4/2019

WOLFF

PATEL

 

M6C

3D DWG

M6C CERTIFICATION DRAWING

USER INSTRUCTIONS

 

MODEL

NEXT ASSY

USED ON

FINISH

PAINT PER PS
PLATE PER PS

COAT PER PS
ANODIZE PER

OTHER

TOLERANCES

 

 

0.03

0.015

1

NONE

REVISION

ECN NO.

DESCRIPTION

APPROVED

DATE

REV

B

10/4/2019

DECIMALS .XX            .XXX

ANGLES

UNLESS OTHERWISE SPECIFIED ABOVE NOTES APPLY.

Industrial Solutions

THIS DOCUMENT MUST BE PROVIDED TO THE CUSTOMER AS PART OF THE INSTRUCTION MANUAL OR AS A SEPARATE DOCUMENT.

 

APPROVALS:

ATEX per Certificate No. TRAC 14ATEX0007X 

IECEx per Certificate No. IECEx TRC 14.0005X

 

MARKINGS:

Ex de IIB T4 Gb   Tamb -40/-20 to +80°C

 

RATINGS:

MAX. VOLTAGE = 28V  

MAX. CURRENT = 160 mA each output

Pmax = 4.48 W each output

AMBIENT TEMPERATURE Tamb:  -40/-20°C ≤ Tamb ≤ 80°C

 

CONDITIONS FOR SAFE USE ("X" MARK):

This product has no user serviceable parts.  Care must be taken during use to ensure that flameproof joints on the Cover and Housing are not damaged.  Repair of 

flameproof joints is not permissible.  Contact Nidec Industrial Solutions for dimensions of flameproof joints.  

 

The circuits shall be limited to overvoltage category I/II/II as defined in IEC 60664-1.

 

The (4) screws that secure the XP5 cover onto the XP5 enclosure require the minimum tensile strength shown below:

  

     MATERIAL               GRADE      MINIMUM TENSILE STRENGTH

     A2 Stainless Steel     A-70         700 Mpa (101.5 KSI)

     A4 Stainless Steel     A-80         800 Mpa (116.0 KSI)

     Carbon Steel            8.8           800 Mpa (116.0 KSI) 

     Alloy Steel               12.9        1220 Mpa (176.9 KSI)

 

Protect the cover seal from sunlight during storage and installation.

 

INSTALLATION NOTES

:

Installation should only be performed by qualified personnel.  Refer to WIRING INSTRUCTIONS in M6C-4, M6C-5 for detailed wiring and installation instructions.

  

The 

installer should refer to the latest edition of the following standards before installing or operating in a Hazardous Location:    

     EN 1127-1 Explosive Atmospheres - Explosion prevention and protection, basic concepts and methodology

     EN 60079-14 Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines) 

     Local electrical code

 

All bolted connections must be secure.  Tighten Cover Screws to 3.4 N-m (30 in-lb) max.  Installer must ensure that the Rotor does not contact the Sensor or any other 

stationary parts. 

 

Encoder Housing must be grounded at one of two specified locations either on the outside or inside of housing.  Use a lock washer or similar means on the external 

ground location to prevent the screw from loosening.  Use anti-corrosion compound on the outside ground location to prevent corrosion of the ground connection.  

Ground screws must be colored green.  The ground conductor size should be equal to, or larger than the power/signal conductors to the encoder.

 

Cable glands and conductors specified by the end user must be suitable for a service temperature of at least 94

°C

.

 

WARNINGS/CAUTIONS:

DO NOT OPEN IN A HAZARDOUS ENVIRONMENT WHILE ENERGIZED.

AVERTISSEMENT : Ne pas ouvrir dans un environnement dangereux, alors qu'il est sous tension.

 

 

THIS DRAWING IDENTIFIES CHARACTERISTICS  REQUIRED FOR 

EQUIPMENT USED IN HAZARDOUS LOCATIONS AND MAY NOT BE 

CHANGED WITHOUT THIRD PARTY APPROVAL. THIRD PARTIES MUST 

BE IDENTIFIED FROM IDENTIFICATION LABELS

.

THIS DOCUMENT MUST BE PROVIDED TO THE CUSTOMER AS PART OF THE INSTRUCTION MANUAL OR AS A SEPARATE DOCUMENT.

 

APPROVALS:

ATEX per Certificate No. TRAC 14ATEX0007X

IECEx per Certificate No. TRC 14.0005X

 

MARKINGS:

Ex d e IIB T4 Gb   TRAC 14ATEX0007X     Tamb = -40/-20

°

 C to +80

°

 C

                               IECEx  TRC 14.0005X    Tamb = -40/-20

°

 C to +80

°

 C

 

RATINGS:

MAX VOLTAGE = 28 V

MAX CURRENT = 160 mA Each Output

PMAX = 4.48 W Each Output

AMBIENT TEMPERATURE:   -20

°

 C to +80

°

 C standard, -40

°

 C to +80

°

 C with mod codes 001 and 005

 

CONDITIONS FOR SAFE USE (“X” MARK):

Installation should only be performed by qualified personnel.  Safety precautions must be taken

during use to ensure that flameproof joints on the Cover and Housing are not damaged.  Repair 

of flameproof joints is not permissible.  Contact the original manufacturer for information on

the flameproof joints.

 

Termination instructions in M6C-4, M6C-5 manual must be followed to ensure “Increased Safety”

rating of entry cover.

 

The M6C “Increased Safety” conduit entry covers must not be opened in Flammable Atmosphere 

or when energized.   Tighten cover screws to 40 in-lb (4.5 N-m) to prevent loosening.

 

The ambient temperature range is -20

°

 C to +80

°

 C standard, -40

°

 C to +80

°

 C with mod codes 001 and 005.

 

Socket head cap screws holding the flameproof cover onto the encoder have minimum yield

strength of 1220 N/mm2.

 

DO NOT OPEN THE M6C HOUSING.  Doing so will void the warranty and may cause the risk of fire or explosion. 

The product has no user serviceable parts.  The unit should be returned to the factory for all repairs.

INSTALLATION NOTES:

Installation should only be performed by qualified personnel.  Safety precautions must be taken to

ensure machinery cannot rotate and all sources of power are removed during installation.

 

Refer to WIRING INSTRUCTIONS in M6C-4, M6C-5 for detailed wiring and installation instructions.

The installer should refer to the latest edition of the following standards before installing or operating

in a Hazardous Location:

      EN 1127-1 Explosive Atmospheres - Explosion prevention and protection, basic concepts and methodology.

      EN 60079-14 Electrical apparatus for explosive gas atmospheres - Part 14:  Electrical Installations in

      hazardous areas (other than mines).

      Local electric code

 

For ambient temperatures below -10

°

 C and above +60° C, use wiring suitable for both minimum and 

maximum ambient temperatures.  At maximum ambient temperature, wire and cable glands must be

rated +100

°

 C or higher.

 

WARNING/CAUTIONS

DO NOT OPEN IN A HAZARDOUS ENVIRONMENT WHILE ENERGIZED.

Содержание M6C-4

Страница 1: ... on the other side for a process computer INSTALLATION CONSIDERATIONS The M6C standard flexible anti rotation bracket will tolerate 0 1 of shaft end float Consideration should be taken when positioning the encoder CAUTION Be careful not to damage clamping fingers during handling Do not tighten clamping collar before installation onto motor shaft Damaging clamping fingers can affect the quality of ...

Страница 2: ...s match 4 Loosen the clamping collar and rotate the motor shaft 180 within the M6C hollow shaft sleeve 5 Make sure the clamping collar is tightened equally on both sides 6 Move the split in the clamping collar over a solid portion of the M6C shaft If excessive housing movement still exists after the above steps it may be necessary to physically bias the attitude of the encoder on the motor shaft w...

Страница 3: ...e Base PPR x 2 48 480 51 512 60 600 See below for addi tional PPR options Z Marker None K 1 4 AB Cycle Sync w AB High T Conduit Box Terminal Block 3 4 NPT W Conduit Box Terminal Block and Wire Gland 000 None 001 Low Temp 40 C 003 Torque Arm B28390 005 Low Temp 40 C Torque Arm RESOLUTIONS OUTPUT RANGE 48 BASE PPR 51 BASE PPR 60 BASE PPR L LOW 240 256 300 H HIGH 960 1024 1200 There are no field repl...

Страница 4: ...ading 6 1 x 109 Revolutions J Maximum Additional Bearing Load 1 10 pounds axial or 30 pounds radial K Shaft Material Black Oxide treated steel L Housing Material Cast aluminum w Polane S Plus polyurethane enamel finish ENVIRONMENTAL A Enclosure Rating IP66 B Operating Temperature 80C to 40 C 40 C optional 20 C standard C Hazardous Locations Ex de IIB T4 Gb Tamb 20 C to 80 C Standard 40 C to 80 C O...

Страница 5: ...OPTIONS REF SIGNAL OPTION T W SIGNAL CODE BLACK RED GREEN YELLOW BLUE GRAY ORANGE WHITE 1 2 3 4 5 6 7 8 COM V ØA ØA ØB ØB Z Z DIFFERENTIAL APPLICATIONS 5 TO 24 VOLTS MARKER SEE LINE DRIVER OPTIONS WIRING DIAGRAMS NOTE Avtron standard warranty applies Copies available upon request Specifications subject to change without notice TYPICAL WIRE 18 AWG 82mm2 multiple pair individually shielded Ground wi...

Страница 6: ...ACKET ARM ASSY ANTI ROTATION ADJUSTABLE BUTTON HD SCREWS 3 8 16 X 50 MOTOR NOTE FOR MAXIMUM STABILITY AND OPERATING CONDITIONS MOUNT THE ANTI ROTATION ARM ASSY WITH THE M6 TACH AS CLOSE AS POSSIBLE TO THE MOTOR HOUSING UTILIZING THE ABOVE MOUNTING PROCEDURE 4 IDENTIFICATION LABEL SEE ABOVE 3 DIMENSIONS IN PARENTHESIS ARE MILLIMETERS 2 ALL DIMENSIONS ARE APPROX 1 WEIGHT 18 LBS MAX OUTLINE DRAWING F...

Страница 7: ...eproof joints ontheCover andHousing arenot damaged Repair of flameproof joints is not permissible Contact the original manufacturer for informationon theflameproof joints Terminationinstructions inM6C 4 M6C 5 manual must be followedtoensure IncreasedSafety rating of entry cover TheM6C IncreasedSafety conduit entry covers must not be openedinFlammableAtmosphere or whenenergized Tightencover screws ...

Отзывы: