Avtron M6C-4 Скачать руководство пользователя страница 5

M6C-4, M6C-5

5

A40346

COMMON

+5 TO +24 VOLTS

*

SIGNAL

GROUND

OUTPUT

BOX

RED

GREEN

BLACK

SINGLE ENDED 

SINGLE PHASE APPLICATIONS

1
2

3

*

(SEE LINE DRIVER OPTIONS)

OUTPUT

BOX

+5 TO +24 VOLTS

*

ØB

ØA
COMMON

GROUND

RED
BLUE

GREEN
BLACK 

2
5

3
1

SINGLE ENDED 

TWO PHASE APPLICATIONS

*

(SEE LINE DRIVER OPTIONS)

REF

SIGNAL

OPTION

“T” & “W”

SIGNAL CODE

BLACK
RED
GREEN
YELLOW
BLUE
GRAY
ORANGE
WHITE

1
2
3
4
5
6
7
8

COM

+V

ØA
ØA
ØB
ØB

Z
Z

DIFFERENTIAL APPLICATIONS

 
+5 TO +24 VOLTS

*

= MARKER

*

(SEE LINE DRIVER OPTIONS)

WIRING DIAGRAMS

NOTE:  Avtron standard warranty applies. Copies available upon request.  

 

Specifications subject to change without notice.

TYPICAL WIRE: 

18 AWG (.82mm

2

), multiple pair, 

 individually shielded. 

Ground wire 14AWG minimum

Line driver option “1” recommended for single ended applications

Содержание M6C-4

Страница 1: ... on the other side for a process computer INSTALLATION CONSIDERATIONS The M6C standard flexible anti rotation bracket will tolerate 0 1 of shaft end float Consideration should be taken when positioning the encoder CAUTION Be careful not to damage clamping fingers during handling Do not tighten clamping collar before installation onto motor shaft Damaging clamping fingers can affect the quality of ...

Страница 2: ...s match 4 Loosen the clamping collar and rotate the motor shaft 180 within the M6C hollow shaft sleeve 5 Make sure the clamping collar is tightened equally on both sides 6 Move the split in the clamping collar over a solid portion of the M6C shaft If excessive housing movement still exists after the above steps it may be necessary to physically bias the attitude of the encoder on the motor shaft w...

Страница 3: ...e Base PPR x 2 48 480 51 512 60 600 See below for addi tional PPR options Z Marker None K 1 4 AB Cycle Sync w AB High T Conduit Box Terminal Block 3 4 NPT W Conduit Box Terminal Block and Wire Gland 000 None 001 Low Temp 40 C 003 Torque Arm B28390 005 Low Temp 40 C Torque Arm RESOLUTIONS OUTPUT RANGE 48 BASE PPR 51 BASE PPR 60 BASE PPR L LOW 240 256 300 H HIGH 960 1024 1200 There are no field repl...

Страница 4: ...ading 6 1 x 109 Revolutions J Maximum Additional Bearing Load 1 10 pounds axial or 30 pounds radial K Shaft Material Black Oxide treated steel L Housing Material Cast aluminum w Polane S Plus polyurethane enamel finish ENVIRONMENTAL A Enclosure Rating IP66 B Operating Temperature 80C to 40 C 40 C optional 20 C standard C Hazardous Locations Ex de IIB T4 Gb Tamb 20 C to 80 C Standard 40 C to 80 C O...

Страница 5: ...OPTIONS REF SIGNAL OPTION T W SIGNAL CODE BLACK RED GREEN YELLOW BLUE GRAY ORANGE WHITE 1 2 3 4 5 6 7 8 COM V ØA ØA ØB ØB Z Z DIFFERENTIAL APPLICATIONS 5 TO 24 VOLTS MARKER SEE LINE DRIVER OPTIONS WIRING DIAGRAMS NOTE Avtron standard warranty applies Copies available upon request Specifications subject to change without notice TYPICAL WIRE 18 AWG 82mm2 multiple pair individually shielded Ground wi...

Страница 6: ...ACKET ARM ASSY ANTI ROTATION ADJUSTABLE BUTTON HD SCREWS 3 8 16 X 50 MOTOR NOTE FOR MAXIMUM STABILITY AND OPERATING CONDITIONS MOUNT THE ANTI ROTATION ARM ASSY WITH THE M6 TACH AS CLOSE AS POSSIBLE TO THE MOTOR HOUSING UTILIZING THE ABOVE MOUNTING PROCEDURE 4 IDENTIFICATION LABEL SEE ABOVE 3 DIMENSIONS IN PARENTHESIS ARE MILLIMETERS 2 ALL DIMENSIONS ARE APPROX 1 WEIGHT 18 LBS MAX OUTLINE DRAWING F...

Страница 7: ...eproof joints ontheCover andHousing arenot damaged Repair of flameproof joints is not permissible Contact the original manufacturer for informationon theflameproof joints Terminationinstructions inM6C 4 M6C 5 manual must be followedtoensure IncreasedSafety rating of entry cover TheM6C IncreasedSafety conduit entry covers must not be openedinFlammableAtmosphere or whenenergized Tightencover screws ...

Отзывы: