Avtron M6C-4 Скачать руководство пользователя страница 4

M6C-4, M6C-5

4

A40346

 ELECTRICAL

A.  Operating Power (Vin)   

   1.  Volts ........................See Line Driver Options 

   2.  Current ....................120mA, no load, typ. each output

B.  Output Format 

   1.  2O/  & Comp (A,A–, B,B–) 

   2.  Marker ....................1/Rev (Z,Z–) 

C.  Signal Type .................Incremental, Square Wave, 50 ±10% Duty Cycle

D.  Direction Sensing ........O/ A leads O/ B for CW rotation viewed from the back  

    

of the tach looking at the non-drive end of the motor.

E.  Transition Sep. ............15% minimum

F.  Frequency Range ........0 to 250 KHz

MECHANICAL

A.  Shaft Inertia .................0.8 to .23 oz. In. sec.

2

 

B. Acceleration ................5,000 RPM/Sec. Maximum 

C.  Starting Torque ...........1.5 to 20 Oz. In.  

D. Speed ........................... 5,000 RPM Max. 

E. Weight .........................18 lbs. Maximum 

F.  Shaft Diameter 

 

  Tolerance ................See drawing on page 5. 

G.  Shaft Engagement ......See drawing on page 5.
H.  Bearing Protection: Shaft seal & double bearing seal. 

I.  Bearing Life with No Additional Loading: 6.1 x 10

9

 Revolutions 

J.   Maximum Additional Bearing Load: 

   1.  10 pounds axial or 30 pounds radial 

K.  Shaft Material: Black Oxide treated steel. 

L.  Housing Material: Cast aluminum w/ Polane S Plus polyurethane enamel finish.

ENVIRONMENTAL

A.  Enclosure Rating: IP66 

B.  Operating Temperature: 80C° to -40°C (-40°C optional, -20°C standard) 

C.  Hazardous Locations: Ex de IIB T4 Gb (Tamb -20°C to +80°C Standard, 

-40°C to +80°C Optional use Modification “001” or “005”)

OUTPUT TERMINATIONS

Terminal Block: EEx e II compression type. Accepts AWG 16 (1.5mm

2

) to AWG 

20 (.52mm

2

) stranded wire. Housing available with 3/4 NPT or optional armored 

cable gland available (at maximum ambient wire and cable glands must be rated 

100°C or better.)

LINE DRIVER OPTIONS

SPECIFICATIONS

OUTPUT OPTIONS

8

Voltage Input (Vin)

5-24 VDC

Output High (Volts)

(Vin)-1 (typ.)

Output Current (milliamps)

200 (avg.), 800 (peak)

Output Low (Volts)

0.4 (typ.)

Protection

BEST Reverse Voltage, Transient, Short Circuit  

(high & low)

Maximum Cable Drive(Feet)

1000 ft. 

Содержание M6C-4

Страница 1: ... on the other side for a process computer INSTALLATION CONSIDERATIONS The M6C standard flexible anti rotation bracket will tolerate 0 1 of shaft end float Consideration should be taken when positioning the encoder CAUTION Be careful not to damage clamping fingers during handling Do not tighten clamping collar before installation onto motor shaft Damaging clamping fingers can affect the quality of ...

Страница 2: ...s match 4 Loosen the clamping collar and rotate the motor shaft 180 within the M6C hollow shaft sleeve 5 Make sure the clamping collar is tightened equally on both sides 6 Move the split in the clamping collar over a solid portion of the M6C shaft If excessive housing movement still exists after the above steps it may be necessary to physically bias the attitude of the encoder on the motor shaft w...

Страница 3: ...e Base PPR x 2 48 480 51 512 60 600 See below for addi tional PPR options Z Marker None K 1 4 AB Cycle Sync w AB High T Conduit Box Terminal Block 3 4 NPT W Conduit Box Terminal Block and Wire Gland 000 None 001 Low Temp 40 C 003 Torque Arm B28390 005 Low Temp 40 C Torque Arm RESOLUTIONS OUTPUT RANGE 48 BASE PPR 51 BASE PPR 60 BASE PPR L LOW 240 256 300 H HIGH 960 1024 1200 There are no field repl...

Страница 4: ...ading 6 1 x 109 Revolutions J Maximum Additional Bearing Load 1 10 pounds axial or 30 pounds radial K Shaft Material Black Oxide treated steel L Housing Material Cast aluminum w Polane S Plus polyurethane enamel finish ENVIRONMENTAL A Enclosure Rating IP66 B Operating Temperature 80C to 40 C 40 C optional 20 C standard C Hazardous Locations Ex de IIB T4 Gb Tamb 20 C to 80 C Standard 40 C to 80 C O...

Страница 5: ...OPTIONS REF SIGNAL OPTION T W SIGNAL CODE BLACK RED GREEN YELLOW BLUE GRAY ORANGE WHITE 1 2 3 4 5 6 7 8 COM V ØA ØA ØB ØB Z Z DIFFERENTIAL APPLICATIONS 5 TO 24 VOLTS MARKER SEE LINE DRIVER OPTIONS WIRING DIAGRAMS NOTE Avtron standard warranty applies Copies available upon request Specifications subject to change without notice TYPICAL WIRE 18 AWG 82mm2 multiple pair individually shielded Ground wi...

Страница 6: ...ACKET ARM ASSY ANTI ROTATION ADJUSTABLE BUTTON HD SCREWS 3 8 16 X 50 MOTOR NOTE FOR MAXIMUM STABILITY AND OPERATING CONDITIONS MOUNT THE ANTI ROTATION ARM ASSY WITH THE M6 TACH AS CLOSE AS POSSIBLE TO THE MOTOR HOUSING UTILIZING THE ABOVE MOUNTING PROCEDURE 4 IDENTIFICATION LABEL SEE ABOVE 3 DIMENSIONS IN PARENTHESIS ARE MILLIMETERS 2 ALL DIMENSIONS ARE APPROX 1 WEIGHT 18 LBS MAX OUTLINE DRAWING F...

Страница 7: ...eproof joints ontheCover andHousing arenot damaged Repair of flameproof joints is not permissible Contact the original manufacturer for informationon theflameproof joints Terminationinstructions inM6C 4 M6C 5 manual must be followedtoensure IncreasedSafety rating of entry cover TheM6C IncreasedSafety conduit entry covers must not be openedinFlammableAtmosphere or whenenergized Tightencover screws ...