M6C-4, M6C-5
4
A40346
ELECTRICAL
A. Operating Power (Vin)
1. Volts ........................See Line Driver Options
2. Current ....................120mA, no load, typ. each output
B. Output Format
1. 2O/ & Comp (A,A–, B,B–)
2. Marker ....................1/Rev (Z,Z–)
C. Signal Type .................Incremental, Square Wave, 50 ±10% Duty Cycle
D. Direction Sensing ........O/ A leads O/ B for CW rotation viewed from the back
of the tach looking at the non-drive end of the motor.
E. Transition Sep. ............15% minimum
F. Frequency Range ........0 to 250 KHz
MECHANICAL
A. Shaft Inertia .................0.8 to .23 oz. In. sec.
2
B. Acceleration ................5,000 RPM/Sec. Maximum
C. Starting Torque ...........1.5 to 20 Oz. In.
D. Speed ........................... 5,000 RPM Max.
E. Weight .........................18 lbs. Maximum
F. Shaft Diameter
Tolerance ................See drawing on page 5.
G. Shaft Engagement ......See drawing on page 5.
H. Bearing Protection: Shaft seal & double bearing seal.
I. Bearing Life with No Additional Loading: 6.1 x 10
9
Revolutions
J. Maximum Additional Bearing Load:
1. 10 pounds axial or 30 pounds radial
K. Shaft Material: Black Oxide treated steel.
L. Housing Material: Cast aluminum w/ Polane S Plus polyurethane enamel finish.
ENVIRONMENTAL
A. Enclosure Rating: IP66
B. Operating Temperature: 80C° to -40°C (-40°C optional, -20°C standard)
C. Hazardous Locations: Ex de IIB T4 Gb (Tamb -20°C to +80°C Standard,
-40°C to +80°C Optional use Modification “001” or “005”)
OUTPUT TERMINATIONS
Terminal Block: EEx e II compression type. Accepts AWG 16 (1.5mm
2
) to AWG
20 (.52mm
2
) stranded wire. Housing available with 3/4 NPT or optional armored
cable gland available (at maximum ambient wire and cable glands must be rated
100°C or better.)
LINE DRIVER OPTIONS
SPECIFICATIONS
OUTPUT OPTIONS
8
Voltage Input (Vin)
5-24 VDC
Output High (Volts)
(Vin)-1 (typ.)
Output Current (milliamps)
200 (avg.), 800 (peak)
Output Low (Volts)
0.4 (typ.)
Protection
BEST Reverse Voltage, Transient, Short Circuit
(high & low)
Maximum Cable Drive(Feet)
1000 ft.