Avtron M6C-4 Скачать руководство пользователя страница 3

M6C-4, M6C-5

3

A40346

Physical properties of cable such as abrasion, tensile strength, 

solvents, marine applications, etc., are dictated by the specific 

application. Requirements for hazardous locations are dictated by 

the relevant codes. General wire electrical requirements wire each 

pair individually shielded with braid or foil with drain wire, 0.05 uF 

maximum total mutual or direct capacitance, outer sheath insulator, 

2,000 ft. max. (see line driver specifications.) Temperature ratings of 

wire and wire glands should be 20°C over the maximum expected 

ambient or motor temperature to allow for temperature rise in the 

M6C itself. Ground wires must be a minimum of 14AWG.

MAINTENANCE

 CAUTION

 

Do not open the M6C housing. Doing so will void the  

 

warranty and may cause the risk of fire or explosion.

M6C PART NUMBERS AND AVAILABLE OPTIONS

 

   

Model

Bore Size

Mounting 

Style

Line Driver

Left & Right 

Output Range

Base 

PPR

Marker

Connector

Modifications

M6C-

0-  Non-Standard  

4-  1"

5-  1 1/8"

S- End of Shaft

8-  5 to 24 VDC

X- None

L-  Low Range  

  (Base PPR x 1/2)

M- Medium Range  

  (Base PPR x 1)

H- High Range  

  (Base PPR x 2)

48- 480

51- 512

60- 600

See below 

for addi-

tional PPR 

options

Z- Marker

– - None 

K-  1/4 AB Cycle 

  Sync w/AB  

 High

T-  Conduit Box,  

  Terminal Block,  

  3/4" NPT

W- Conduit Box,  

  Terminal Block  

  and Wire Gland

000- None 

001- Low Temp (-40°C) 

003- Torque Arm B28390 

005- Low Temp (-40°C) &  

 

   Torque Arm

RESOLUTIONS

OUTPUT 

RANGE

-48 BASE PPR

-51 BASE PPR

-60 BASE PPR

L = LOW

240

256

300 

H = HIGH

960

1024

1200

There are no field replaceable parts in an M6C. The unit should be 

returned to the factory for all repairs.

Build up of large amounts of contamination are to be avoided, 

therefore periodic external cleaning is recommended.

The condition of the bearings is important to the safety of the 

explosion-proof housing. The bearing manufacturer’s rated life (see 

specifications) can be adversely affected by application specific 

conditions. If the unit shows signs of bearing wear indicated by noise 

or degradation of the electrical signal output, it should be returned to 

the factory for repair.

OUTPUT RANGE MUST = M  

EXTENDED RESOLUTIONS

BASE PPR

PPR

BASE PPR

PPR

A0

NON-STD

AW

1000

BC

50

BK

1365

AF

60

CX

1500

AK

80

A3

2000

AG

100

A4

2048

AH

120

BA

2400

AA

128

A5

2500

AM

200

CG

3000

AE

360

AT

3072

AC

400

A7

3600

48

480

BB

4000

AQ

500

AD

4096

51

512

A8

4800

60

600

A9

5000

AU

720

A2

8192

AV

900

BL

16384

Содержание M6C-4

Страница 1: ... on the other side for a process computer INSTALLATION CONSIDERATIONS The M6C standard flexible anti rotation bracket will tolerate 0 1 of shaft end float Consideration should be taken when positioning the encoder CAUTION Be careful not to damage clamping fingers during handling Do not tighten clamping collar before installation onto motor shaft Damaging clamping fingers can affect the quality of ...

Страница 2: ...s match 4 Loosen the clamping collar and rotate the motor shaft 180 within the M6C hollow shaft sleeve 5 Make sure the clamping collar is tightened equally on both sides 6 Move the split in the clamping collar over a solid portion of the M6C shaft If excessive housing movement still exists after the above steps it may be necessary to physically bias the attitude of the encoder on the motor shaft w...

Страница 3: ...e Base PPR x 2 48 480 51 512 60 600 See below for addi tional PPR options Z Marker None K 1 4 AB Cycle Sync w AB High T Conduit Box Terminal Block 3 4 NPT W Conduit Box Terminal Block and Wire Gland 000 None 001 Low Temp 40 C 003 Torque Arm B28390 005 Low Temp 40 C Torque Arm RESOLUTIONS OUTPUT RANGE 48 BASE PPR 51 BASE PPR 60 BASE PPR L LOW 240 256 300 H HIGH 960 1024 1200 There are no field repl...

Страница 4: ...ading 6 1 x 109 Revolutions J Maximum Additional Bearing Load 1 10 pounds axial or 30 pounds radial K Shaft Material Black Oxide treated steel L Housing Material Cast aluminum w Polane S Plus polyurethane enamel finish ENVIRONMENTAL A Enclosure Rating IP66 B Operating Temperature 80C to 40 C 40 C optional 20 C standard C Hazardous Locations Ex de IIB T4 Gb Tamb 20 C to 80 C Standard 40 C to 80 C O...

Страница 5: ...OPTIONS REF SIGNAL OPTION T W SIGNAL CODE BLACK RED GREEN YELLOW BLUE GRAY ORANGE WHITE 1 2 3 4 5 6 7 8 COM V ØA ØA ØB ØB Z Z DIFFERENTIAL APPLICATIONS 5 TO 24 VOLTS MARKER SEE LINE DRIVER OPTIONS WIRING DIAGRAMS NOTE Avtron standard warranty applies Copies available upon request Specifications subject to change without notice TYPICAL WIRE 18 AWG 82mm2 multiple pair individually shielded Ground wi...

Страница 6: ...ACKET ARM ASSY ANTI ROTATION ADJUSTABLE BUTTON HD SCREWS 3 8 16 X 50 MOTOR NOTE FOR MAXIMUM STABILITY AND OPERATING CONDITIONS MOUNT THE ANTI ROTATION ARM ASSY WITH THE M6 TACH AS CLOSE AS POSSIBLE TO THE MOTOR HOUSING UTILIZING THE ABOVE MOUNTING PROCEDURE 4 IDENTIFICATION LABEL SEE ABOVE 3 DIMENSIONS IN PARENTHESIS ARE MILLIMETERS 2 ALL DIMENSIONS ARE APPROX 1 WEIGHT 18 LBS MAX OUTLINE DRAWING F...

Страница 7: ...eproof joints ontheCover andHousing arenot damaged Repair of flameproof joints is not permissible Contact the original manufacturer for informationon theflameproof joints Terminationinstructions inM6C 4 M6C 5 manual must be followedtoensure IncreasedSafety rating of entry cover TheM6C IncreasedSafety conduit entry covers must not be openedinFlammableAtmosphere or whenenergized Tightencover screws ...