Prior to installation, it is important to check if there will be any equipment in the vicinity that may interfere 

with the loop’s magnetic field, such as large transformers, high power cables or substations. It is also 

important to ensure that no equipment will be adversely affected by the loop field, such as sensitive data or 

signal cables. In these cases, it may not be possible to cover some or any of the required area with an 

induction loop. 

 

The cable gauge will depend upon the total length of the induction loop. Usually, the loop will be installed 

around the perimeter of the listening area. However, there are various techniques which can be employed to 

build arrays to vary the shape and strength of the field. In general, calculations outlined here are based upon 

a perimeter installation. 

 

It is recommended to use good quality insulated pure copper cable for the induction loop. The cable gauge 

used will need to be determined by the total length of the cable run. The LA-series loop amplifiers are 

designed to operate with a load of between 0.2Ω and 2Ω. The following equation can be used to calculate 

the total cable resistance, which will show if the gauge is correct. 

 

R = 

Cable length (m) 

x   0.01786Ω*mm²/m (specific resistance of Copper)  

 

Cable CSA (mm²) 

 

So, for a cable 80m long with a Cross-Sectional Area (CSA) of 1.5mm²…    R = 80/1.5 x 0.01786 = 0.9525Ω 

 

So, this gauge of wire (1.5mm²) would be OK for the 80m run because it is between 0.2Ω and 2Ω 

 

As a quick reference, refer to the table below. 

 

Cable CSA (mm²) 

1.0 

1.5 

2.5 

4.0 

Total Loop Length 

60m max. 

110m max. 

200m max.

 

Over 200m

 

 

The wire may be run in plastic conduit but not in any metal containment so as not to impair the magnetic 

flux. The ideal height to install the cable depends upon the width of the loop (i.e. the narrowest dimension 

relative to the listener). The optimum output will be achieved if the cable is installed 14% of the loop width 

higher or lower than the plane of listening (ear height).  

 

In practical terms, the loop is usually installed onto skirting boards, under flooring or at ceiling height so that 

it is unobtrusive. It is recommended to avoid varying height levels as much as possible to avoid anomalies in 

field strength.  

 

For irregular shaped areas or larger than the loop amplifier’s capacity, multiple induction loops may be 

required for coverage. Connecting further loop amplifiers using the Slave connection will enable multiple 
loops to be used together. 

 

 

Содержание Adastra LA Series

Страница 1: ...LA SERIES LOOP AMPLIFIERS Item ref 952 864UK 952 867UK User Manual Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty ...

Страница 2: ...AZARDOUS LIVE and should only be connected by qualified personnel 15 Ensure that the apparatus is connected to a mains socket with a protective EARTH connection 16 Ensure correct operation of the mains switch Warning To prevent the risk of fire or electric shock do not expose any components to rain or moisture If liquids are spilled on the casing stop using immediately allow unit to dry out and ha...

Страница 3: ...should be installed in accordance with BS7594 Front panel 1 Channel 1 input level control 6 Loop current master level control 2 Channel 2 input level control 7 Siren indicator 3 Channel 3 input level control 8 Loop current level indicator 4 Bass EQ adjustment 9 Power switch and indicator 5 Treble EQ adjustment Rear panel 10 Mains voltage selector 15 Unbalanced RCA inputs 11 Combined IEC mains inle...

Страница 4: ...his socket gives 2 wiring options as shown below Connecting a mono 6 3mm plug will function as a slave output A TRS plug with signal connected to the ring will be needed for a slave input from another loop amplifier Alarm contacts 13 are provided which will emit a siren on the induction loop when the connection is made These can be connected to an emergency switch or alarm panel contacts to activa...

Страница 5: ...quation can be used to calculate the total cable resistance which will show if the gauge is correct R Cable length m x 0 01786Ω mm m specific resistance of Copper Cable CSA mm So for a cable 80m long with a Cross Sectional Area CSA of 1 5mm R 80 1 5 x 0 01786 0 9525Ω So this gauge of wire 1 5mm would be OK for the 80m run because it is between 0 2Ω and 2Ω As a quick reference refer to the table be...

Страница 6: ...e Phantom switch to OFF For line inputs select LINE on the DIP switches For channel 1 there is an option for PRIORITY over the other two channels which will mute the output of channels 2 and 3 when there is an input to channel 1 If the loop amplifier is to be used in conjunction with a PA system with loudspeakers connect the line or aux output from the PA system to a Line input on the loop amplifi...

Страница 7: ...s are at maximum level the Peak Current indicator does not show overloading It is recommended to use an induction loop receiver 952 855UK to check the audio from the induction loop Adjust the Loop Current control to set the main audio level from the induction loop The Metal Loss Correction control 18 enhances higher audio frequencies which may be absorbed by metal architectural features and applia...

Страница 8: ...ures within the architecture close to the loop Avoid changes in height of the loop cable running over door frames etc Loop field interfering with other audio equipment Ensure that the loop cable is twisted between the loop and the loop amplifier If necessary form a cancellation loop to avoid affecting other equipment Siren activated Ensure that the alarm contacts are not accidentally shorted out P...

Отзывы: