background image

 

   

952.864UK, 952.867UK User Manual 

Specifications 

 

Model 

LA-300 mkII (952.864UK) 

LA-600 mkII (952.867UK) 

Power supply 

110/240Vac, 50/60Hz (IEC) 

Fuse 

T1A 250V 

T2A 250V 

Area coverage 

300m² max. 

600m² max. 

Frequency response 

50Hz - 5kHz (±3dB) 

Input sensitivity : line 

-6dBu/6k Ohms 

Input sensitivity : mic 

-56dBu/2k Ohms 

Signal to noise ratio 

75dB (line), 60dB (mic) 

THD 

<1% 

Rack height 

1U 

2U 

Dimensions 

483 x 235 x 44mm 

483 x 235 x 88mm 

Weight 

5.95kg 

4.22kg 

 

 

Troubleshooting 

 

No power indicator when 

switched on 

Check mains is connected and switched on at the socket 
Check that the mains fuse is not blown – refer to qualified service personnel 
If the fuse is blown, check that the loop contacts were not shorted out 

Peak current indicators are 

not showing any signal 

Check input connections are OK and that a signal is present on the input 
Check that the loop is intact and connected to the amplifier properly 
Increase channel level controls and Loop current if necessary 

Dead spots within 

induction loop field 

Check for large metal structures within the architecture close to the loop 
Avoid changes in height of the loop cable (running over door frames etc.) 

Loop field interfering with 

other audio equipment 

Ensure that the loop cable is twisted between the loop and the loop amplifier 
If necessary, form a cancellation loop to avoid affecting other equipment  

Siren activated 

Ensure that the alarm contacts are not accidentally shorted out. 

Peak indicators mainly 

showing overload (red) 

Loop current or input levels may be too high, decrease the relevant controls 
Check that the loop is not shorted or grounded at any point 

Loop current is very low 

Increase input signal, channel levels and loop current controls as needed 

Poor quality audio from 

the loop 

If there are metal structures nearby, increase metal loss correction level 
Use Bass and Treble controls to help improve intelligibility 

 
 

 
 
 

 

 

 

Disposal:

 The “Crossed Wheelie Bin” symbol on the product means that the product is classed as Electrical or  

Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life.  

The goods must be disposed of according to your local council guidelines. 

 
 

Errors and omissions excepted. 

 

Copyright© 2016. AVSL Group Ltd. 

 

Содержание Adastra LA Series

Страница 1: ...LA SERIES LOOP AMPLIFIERS Item ref 952 864UK 952 867UK User Manual Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty ...

Страница 2: ...AZARDOUS LIVE and should only be connected by qualified personnel 15 Ensure that the apparatus is connected to a mains socket with a protective EARTH connection 16 Ensure correct operation of the mains switch Warning To prevent the risk of fire or electric shock do not expose any components to rain or moisture If liquids are spilled on the casing stop using immediately allow unit to dry out and ha...

Страница 3: ...should be installed in accordance with BS7594 Front panel 1 Channel 1 input level control 6 Loop current master level control 2 Channel 2 input level control 7 Siren indicator 3 Channel 3 input level control 8 Loop current level indicator 4 Bass EQ adjustment 9 Power switch and indicator 5 Treble EQ adjustment Rear panel 10 Mains voltage selector 15 Unbalanced RCA inputs 11 Combined IEC mains inle...

Страница 4: ...his socket gives 2 wiring options as shown below Connecting a mono 6 3mm plug will function as a slave output A TRS plug with signal connected to the ring will be needed for a slave input from another loop amplifier Alarm contacts 13 are provided which will emit a siren on the induction loop when the connection is made These can be connected to an emergency switch or alarm panel contacts to activa...

Страница 5: ...quation can be used to calculate the total cable resistance which will show if the gauge is correct R Cable length m x 0 01786Ω mm m specific resistance of Copper Cable CSA mm So for a cable 80m long with a Cross Sectional Area CSA of 1 5mm R 80 1 5 x 0 01786 0 9525Ω So this gauge of wire 1 5mm would be OK for the 80m run because it is between 0 2Ω and 2Ω As a quick reference refer to the table be...

Страница 6: ...e Phantom switch to OFF For line inputs select LINE on the DIP switches For channel 1 there is an option for PRIORITY over the other two channels which will mute the output of channels 2 and 3 when there is an input to channel 1 If the loop amplifier is to be used in conjunction with a PA system with loudspeakers connect the line or aux output from the PA system to a Line input on the loop amplifi...

Страница 7: ...s are at maximum level the Peak Current indicator does not show overloading It is recommended to use an induction loop receiver 952 855UK to check the audio from the induction loop Adjust the Loop Current control to set the main audio level from the induction loop The Metal Loss Correction control 18 enhances higher audio frequencies which may be absorbed by metal architectural features and applia...

Страница 8: ...ures within the architecture close to the loop Avoid changes in height of the loop cable running over door frames etc Loop field interfering with other audio equipment Ensure that the loop cable is twisted between the loop and the loop amplifier If necessary form a cancellation loop to avoid affecting other equipment Siren activated Ensure that the alarm contacts are not accidentally shorted out P...