background image

 

   

952.864UK, 952.867UK User Manual 

Operation 

 

The front panel controls on the loop amplifier are recessed and can be adjusted using a flat blade 

screwdriver. This is to avoid tampering or mal-adjustment after the correct settings have been applied. 

Where new or unsupervised operators are making adjustments to equipment in the venue, they may not be 

aware if they have adjusted the induction loop settings unless they themselves are a hearing aid user. 

 

Set the Ch.1, Ch.2, Ch.3 and Loop Current controls (1, 2, 3, 6) to minimum and keep the Bass and Treble 

controls (4, 5) in the mid position (12 o’clock) 

 

Power up the loop amplifier and increase the Loop Current control (6) part way. 

 

Whilst playing a signal into one of the input channels, gradually increase the level (1, 2 or 3) until the peak 

current indicator (8) shows movement. 

 

The optimum operating level is achieved if the channel level controls are set so that if all connected signals 

are at maximum level, the Peak Current indicator does not show overloading.  

 

It is recommended to use an induction loop receiver (952.855UK) to check the audio from the induction loop. 

Adjust the Loop Current control to set the main audio level from the induction loop. 

 

The Metal Loss Correction control (18) enhances higher audio frequencies which may be absorbed by metal 

architectural features and appliances within the induction loop area. If the building has a lot of metal 

structure or reinforced concrete in the vicinity of the loop, use this control to adjust the audio quality of the 

loop signal. 

 

Adjust Bass and Treble controls (4, 5) to set the tonal characteristics of the audio from the induction loop. 
The mid-point (12 o’clock) is the zero position. Turning to the left of the mid-point will cut Bass or Treble and 

to the right of the mid-point will boost Bass or Treble. 

 

When the induction loop is not required, ensure that no hearing aid users are remaining within the loop area 

and switch off the loop amplifier (leaving the settings in position will ensure that the induction loop is set up 

correctly for the next usage)  

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Adastra LA Series

Страница 1: ...LA SERIES LOOP AMPLIFIERS Item ref 952 864UK 952 867UK User Manual Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty ...

Страница 2: ...AZARDOUS LIVE and should only be connected by qualified personnel 15 Ensure that the apparatus is connected to a mains socket with a protective EARTH connection 16 Ensure correct operation of the mains switch Warning To prevent the risk of fire or electric shock do not expose any components to rain or moisture If liquids are spilled on the casing stop using immediately allow unit to dry out and ha...

Страница 3: ...should be installed in accordance with BS7594 Front panel 1 Channel 1 input level control 6 Loop current master level control 2 Channel 2 input level control 7 Siren indicator 3 Channel 3 input level control 8 Loop current level indicator 4 Bass EQ adjustment 9 Power switch and indicator 5 Treble EQ adjustment Rear panel 10 Mains voltage selector 15 Unbalanced RCA inputs 11 Combined IEC mains inle...

Страница 4: ...his socket gives 2 wiring options as shown below Connecting a mono 6 3mm plug will function as a slave output A TRS plug with signal connected to the ring will be needed for a slave input from another loop amplifier Alarm contacts 13 are provided which will emit a siren on the induction loop when the connection is made These can be connected to an emergency switch or alarm panel contacts to activa...

Страница 5: ...quation can be used to calculate the total cable resistance which will show if the gauge is correct R Cable length m x 0 01786Ω mm m specific resistance of Copper Cable CSA mm So for a cable 80m long with a Cross Sectional Area CSA of 1 5mm R 80 1 5 x 0 01786 0 9525Ω So this gauge of wire 1 5mm would be OK for the 80m run because it is between 0 2Ω and 2Ω As a quick reference refer to the table be...

Страница 6: ...e Phantom switch to OFF For line inputs select LINE on the DIP switches For channel 1 there is an option for PRIORITY over the other two channels which will mute the output of channels 2 and 3 when there is an input to channel 1 If the loop amplifier is to be used in conjunction with a PA system with loudspeakers connect the line or aux output from the PA system to a Line input on the loop amplifi...

Страница 7: ...s are at maximum level the Peak Current indicator does not show overloading It is recommended to use an induction loop receiver 952 855UK to check the audio from the induction loop Adjust the Loop Current control to set the main audio level from the induction loop The Metal Loss Correction control 18 enhances higher audio frequencies which may be absorbed by metal architectural features and applia...

Страница 8: ...ures within the architecture close to the loop Avoid changes in height of the loop cable running over door frames etc Loop field interfering with other audio equipment Ensure that the loop cable is twisted between the loop and the loop amplifier If necessary form a cancellation loop to avoid affecting other equipment Siren activated Ensure that the alarm contacts are not accidentally shorted out P...

Отзывы: