background image

Features

The 

VECTOR Plus 

GSM interface is used, toghether with an approved telephone set or dialler,

to send and 

receive

 telephone calls through the GSM network, when PSTN line is missing. 

The interface continuously monitors the PSTN line; when a fault condition is detected 

VECTOR

Plus

 switches the telephone equipment connected to its terminals to an internal telephone line

simulation circuit, able to manage calling procedures eventually started by the telephone
equipment, including dial tone and busy tone generation, dialling sequence recognition and
ringng signal generation. Thus 

VECTOR Plus

 can be used in a 

bidirectional 

way: to send

and/or receive GSM telephone calls.
Additionally

VECTOR Plus

 can send technical and alarm SMS messages to a maximum of 50

telephone numbers.

VECTOR Plus

 has also the possibility to send a periodic SMS message (autotest) within a

programmable time interval.

Operation

In normal installations, 

VECTOR Plus

 is connected to PSTN line, to alarm telephone dialler and

to telephone handsets of the premise. When the PSTN line voltage (normally 48V) goes below
about 35V, 

VECTOR Plus

 starts monitoring the line looking for the dial tone frequency (425Hz

typical). If that signal is not detected within 30 seconds, the interface switches automaticly to
"GSM mode", bringing the alarm dialler to the internal telephone line simulation circuit, whereas
the telephone sets are bypassed directly to the PSTN line.
In this condition, if the dialler attempts to execute a telephone call, 

VECTOR Plus

 generates the

dial tone signal like the normal telephone line, and waits the dialling sequence from the external
device (only DTMF dialling is accepted). After the dialling sequence is completed the call is
routed through the GSM unit and 

VECTOR Plus

 generates the ringing tone and/or busy tone.

Once the GSM connection is established the voice channel stays open allowing data and voice
signals transfer between the dialler and the called party. At the end of the call, as the dialler
realeases the simulated PSTN line, the GSM connection is interrupted. When terminal "GSM -"
is open, 

VECTOR Plus

 waits 60 seconds, after a call through the GSM channel, before

switching back to "PSTN line mode" (normal mode), provided that PSTN line voltage has
returned to its normal value (aprox. 48V).
When the "GSM" terminal is closed to negative or in case of permanent fault of PSTN line,

VECTOR Plus

 interface allows receiving calls through the GSM channel, since, when an

incoming call is detected by the GSM unit, a valid RING signal is generated at the simulated line
terminals of 

VECTOR Plus

, causing the ring detector of the dialler or the ringing bell of a

telephone to be activated. 

Technical characteristics

Power supply voltage:

 12V=

Supply voltage tolerance: 

11.5 - 15 V=

Current consumption:

 300 mA / max 500 mA 

(when charging GSM battery, if any)

Recommended backup battery:

 12V / 1.2 Ah

Dialling mode supported:

  multifrequency (DTMF) 

Dial tone:

 425Hz continuous or cadenced 

(for Italy)

Busy Tone:

 (425Hz) pulsed

Transmission Protocols supported:

ID CONTACT, FAST, SLOW, SEIA, SIA, VOCAL and half duplex protocols 

(

FAX and MODEM like

protocols are NOT supported)

Dimensions (h x l x w) (mm):

 225 x 210 x 80

GSM compatibilities

 

(See technical updates sheet)

3

Содержание VECTOR Plus

Страница 1: ...Curtarolo Padova Italy www avselectronics com VECTOR Plus Bidirectional INTERFACE INSTALLATION MANUAL IST0401V2 1 QUALITY SYSTEM ISO9001 ...

Страница 2: ...s 8 sms functions 7 display module connection 7 plugging in sim card antenna jack 7 gsm engine connection 6 settings 6 input and output 6 leds 6 dip switches 5 jumpers and trimmers 5 testing vector plus 5 other display indications 4 display module 4 installation 4 important warnings 3 gsm compatibilities see technical updates sheet 3 technical characteristics 3 operation 3 features 2 ...

Страница 3: ...lus generates the dial tone signal like the normal telephone line and waits the dialling sequence from the external device only DTMF dialling is accepted After the dialling sequence is completed the call is routed through the GSM unit and VECTOR Plus generates the ringing tone and or busy tone Once the GSM connection is established the voice channel stays open allowing data and voice signals trans...

Страница 4: ......

Страница 5: ... level 5 Battery problem only when using standard cell phone 6 Unknown general problem Testing VECTOR Plus In order to verify the efficiency and the signal quality of the GSM channel we suggest the following test connect a normal telephone set to terminals Ac Bc of the interface and close to negative the terminal GSM Power up the unit and wait the initialization process is completed see display Ex...

Страница 6: ...F DIP 1 OFF LEDs LD1 shows the GSM module operation status flashing GSM module is registered in the network and in stand by on a GSM call is taking place off the GSM module is NOT correctly registered in the network failure condition LD2 must be always ON indicating that the GSM module is working NOTE this two leds will activate only when using the industrial GSM module Input and output GSM input ...

Страница 7: ...nsert SIM Card 1 Insert SIM Card completely into slot C until it clicks inside the module To remove SIM Card 1 Press and release the SIM Card to cause it to be ejected through the slot Antenna jack Place the male connector of the antenna cable into the female one of the module and apply slight pressure in the axis direction to click it into the module Do not force or bend the cable sideway To remo...

Страница 8: ...numbers because it is the one which technical SMS messages are sent to by default otherwise differently specified in configuration parameter 1 Apart from the technical SMS that are automaticly sent by VECTOR Plus once they has been enabled through the configuration numbers the remaining SMS stored into the SIM card by the installer to communicate any kind of alarm or status information can be sent...

Страница 9: ...d up with a different text to be sent by command when needed TT is the position into the SIM card phonebook of the telephone number to which the SMS message has to be sent Like for the text messages the position of telephone numbers also depends on the order they were stored into the SIM card when programmed Issuing 99 as the value of TT the selected SMS message will be sent to all telephone numbe...

Страница 10: ...the interface while the telephone number is being dialled NOTE 1 using AVS ELECTRONICS diallers or control panels setting to 0 the number of attempts of telephone calls will cause the dialler to make one single calling attempt NOTE 2 if the telephone number for SMS activation is not the first number called by the dialler once the GSM input terminal of VECTOR Plus has received the pulse to negative...

Страница 11: ...6 5 4 3 2 1 Telephone number Name saved Posit on M add 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 Telephone number Name saved Posit on M add 14 13 12 11 10 9 8 7 6 5 4 3 tecn 2 tecn 1 tecn SMS Description N SMS 28 27 26 25 24 23 22 21 20 19 18 17 16 15 SMS Description N SMS ...

Страница 12: ...ugana 63 35010 Padova ITALY Tel 049 96 98 411 Fax 049 96 98 407 avs avselectronics com www avselectronics com AVS ELECTRONICS S p A reserves the right to modify the technical and esthetical characteristic of the products at any time ...

Отзывы: