SMS functions
The phone numbers to which SMS messages are going to be sent and the SMS messages
text, must be stored into the SIM card. To execute this operation use a normal cell phone.
Before programming the SIM card, please erase completely the existing contents that could be
stored into it. Note that the first three (3) SMS messages stored into the SIM card are used for
technical purposes, and are sent automaticly by
VECTOR Plus
when the respective monitoring
functions are enabled. This messages are:
SMS nr. 1:
PSTN line fault.
SMS nr. 2:
PSTN line restore
SMS nr. 3:
Autotest
NOTE: if one or more of the above technical messages is NOT required, it is possible to store a different
message in the corresponding SIM card space to be sent "by command" as will be described in the
following chapters.
To enable/disable the functions that send technical SMS messages automaticly, two special
numbers must be stored into the SIM card phonebook, that are used to configure the system.
This two numbers has to be associated to the
names
"1"
and
"2"
(instead of "Smith" or "Johnson")
.
The digits included in the number under name
"1"
determine wheather the three types of
technical SMS messages are to be sent or not, and wheather the technical messages are to be
sent to all the telephone numbers present in the phonebook
(max. 50)
or only to the first one. The
number stored under name
"2"
indicates the autotest repetition intervall
(in hours: from 0 to 255)
.
All the telephone numbers to which the SMS messages will be sent must be stored into the SIM
card phone book, keeping in mind that the first number stored has a
priority
over the rest of the
numbers, because it is the one which technical SMS messages are sent to by default, otherwise
differently specified in configuration parameter
"1"
.
Apart from the technical SMS, that are automaticly sent by
VECTOR Plus
once they has been
enabled through the configuration numbers, the remaining SMS stored into the SIM card by the
installer to communicate any kind of alarm or status information, can be sent through the
VECTOR Plus
interface only in
"by command"
mode, issuing special DTMF sequences at
terminals Ac - Bc like executing a normal telephone call. Note that, for alarm or status SMS
messages to be sent, it is necessary that
VECTOR Plus
interface is operating in "GSM mode",
therefore, it is suggested to use an output from the telephone dialler or control panel to force
VECTOR Plus
into GSM mode through terminal
"GSM"
, before issuing the proper DTMF
sequence to send the SMS. This is not necessary if the equipment is already functionning in
permanent GSM mode, with terminal "GSM" always connected to negative.
Parameters programming (automatic SMS)
SIM card phonebook .-
Parameter "1":
the values stored under this name into the phonebook determine wheather
technical SMS messges must be sent or not.
Including the digit
1
in the number enables sending the "
PSTN line fault"
SMS messages.
Including the digit
2
in the number enables sending the
"PSTN line restore"
SMS message.
Including the digit
3
in the number enables sending the
"Autotest"
SMS message.
Including the digit
8
in the number, technical SMS messages are sent to all telephone numbers
present in the phonebook
(max. 50)
, otherwise they are sent only to the
first
telephone number of
the phonebook.
Parameter "2":
the value stored under this name into the phonebook represents the repetition
intervall
(in hours)
, of the autotest SMS message. This value should be between 0 and 255.