Dialler programming to send "by command" SMS messages

To make a telephone dialler connected to 

VECTOR Plus

 activate SMS messages "by

command", the following steps are required:

1:

 program one of the telephone numbers of the dialler with the proper digits sequence

(0000nnTT)

 as explained hereon.

2:

 associate to that telephone number some default communication protocol.

3:

 program the dialler to make one single calling attempt to that telephone number. If there are

repetitions, the SMS message will be sent many times.

4: 

program an output from the dialler or control panel to activate by a few seconds bringing to

negative "-" the "GSM" input terminal of the interface, while the telephone number is being
dialled.

NOTE 1: using AVS ELECTRONICS diallers or control panels, setting to "0" the number of attempts of
telephone calls will cause the dialler to make one single calling attempt.
NOTE 2: if the telephone number for SMS activation is not the first number "called" by the dialler, once the
"GSM" input terminal of VECTOR Plus has received the pulse to negative, all telephone calls previous to
the SMS activation number will be executed through the GSM channel, while successive ones will occur
over PSTN line.

Example:
Tel. numb 1: alarm telephone call
Tel. numb 2: alarm telephone call
Tel. numb 3: alarm telephone call
Tel. numb 4: 

SMS activation command

 

Tel. numb 5: alarm telephone call
Tel. numb 6: alarm telephone call

x

x

PSTN line

x

x

x

x

GSM 

Call to #6

Call to #5

SMS cmd #4

Call to #3

Call to #2

Call to #1

10

Содержание VECTOR Plus

Страница 1: ...Curtarolo Padova Italy www avselectronics com VECTOR Plus Bidirectional INTERFACE INSTALLATION MANUAL IST0401V2 1 QUALITY SYSTEM ISO9001 ...

Страница 2: ...s 8 sms functions 7 display module connection 7 plugging in sim card antenna jack 7 gsm engine connection 6 settings 6 input and output 6 leds 6 dip switches 5 jumpers and trimmers 5 testing vector plus 5 other display indications 4 display module 4 installation 4 important warnings 3 gsm compatibilities see technical updates sheet 3 technical characteristics 3 operation 3 features 2 ...

Страница 3: ...lus generates the dial tone signal like the normal telephone line and waits the dialling sequence from the external device only DTMF dialling is accepted After the dialling sequence is completed the call is routed through the GSM unit and VECTOR Plus generates the ringing tone and or busy tone Once the GSM connection is established the voice channel stays open allowing data and voice signals trans...

Страница 4: ......

Страница 5: ... level 5 Battery problem only when using standard cell phone 6 Unknown general problem Testing VECTOR Plus In order to verify the efficiency and the signal quality of the GSM channel we suggest the following test connect a normal telephone set to terminals Ac Bc of the interface and close to negative the terminal GSM Power up the unit and wait the initialization process is completed see display Ex...

Страница 6: ...F DIP 1 OFF LEDs LD1 shows the GSM module operation status flashing GSM module is registered in the network and in stand by on a GSM call is taking place off the GSM module is NOT correctly registered in the network failure condition LD2 must be always ON indicating that the GSM module is working NOTE this two leds will activate only when using the industrial GSM module Input and output GSM input ...

Страница 7: ...nsert SIM Card 1 Insert SIM Card completely into slot C until it clicks inside the module To remove SIM Card 1 Press and release the SIM Card to cause it to be ejected through the slot Antenna jack Place the male connector of the antenna cable into the female one of the module and apply slight pressure in the axis direction to click it into the module Do not force or bend the cable sideway To remo...

Страница 8: ...numbers because it is the one which technical SMS messages are sent to by default otherwise differently specified in configuration parameter 1 Apart from the technical SMS that are automaticly sent by VECTOR Plus once they has been enabled through the configuration numbers the remaining SMS stored into the SIM card by the installer to communicate any kind of alarm or status information can be sent...

Страница 9: ...d up with a different text to be sent by command when needed TT is the position into the SIM card phonebook of the telephone number to which the SMS message has to be sent Like for the text messages the position of telephone numbers also depends on the order they were stored into the SIM card when programmed Issuing 99 as the value of TT the selected SMS message will be sent to all telephone numbe...

Страница 10: ...the interface while the telephone number is being dialled NOTE 1 using AVS ELECTRONICS diallers or control panels setting to 0 the number of attempts of telephone calls will cause the dialler to make one single calling attempt NOTE 2 if the telephone number for SMS activation is not the first number called by the dialler once the GSM input terminal of VECTOR Plus has received the pulse to negative...

Страница 11: ...6 5 4 3 2 1 Telephone number Name saved Posit on M add 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 Telephone number Name saved Posit on M add 14 13 12 11 10 9 8 7 6 5 4 3 tecn 2 tecn 1 tecn SMS Description N SMS 28 27 26 25 24 23 22 21 20 19 18 17 16 15 SMS Description N SMS ...

Страница 12: ...ugana 63 35010 Padova ITALY Tel 049 96 98 411 Fax 049 96 98 407 avs avselectronics com www avselectronics com AVS ELECTRONICS S p A reserves the right to modify the technical and esthetical characteristic of the products at any time ...

Отзывы: