6.8.36 SIO WB 627 / SIO SMSC311X Configuration
Feature
Options
Description
COM A-D
Enabled, Disabled
Enable or disable COM A-D on Winbond SIO
COM A-DSetting:
Auto,
I/O 3F8h, IRQ 4
I/O 3F8h, IRQ 3, 4, 5, 6, 7,
10, 11, 12
I/O 2F8h, IRQ 3, 4, 5, 6, 7,
10, 11, 12
I/O 3E8h, IRQ 3, 4, 5, 6, 7,
10, 11, 12
I/O 2E8h, IRQ 3, 4, 5, 6, 7,
10, 11, 12
Resource setting for COM A-D on Winbond SIO
LPT:
Disabled, Enabled
Enable or disable LPT on Winbond SIO
LPT Setting:
Auto,
I/O 378h, IRQ 5, 7
I/O 278, IRQ 5, 7
Resource setting for LPT A on Winbond SIO
LPT Mode:
SPP, EPP 1.9, ECP, ECP +
EPP 1.9, Printer Mode, EPP
1.7, ECP+EPP 1.7
Mode setting for LPT on Winbond SIO
PS/2 controller
Enabled, Disabled
Enable or disable the PS/2 controller.
HWM Interface
Enabled, Disabled
Enable or disable the hardware monitoring interface. If enabled, the
base address 0x0290 will be used.