20
- User and Installation Manual
AvMap
EngiBOX
5.1.5 Date and time:
•
Rotate the knob to select month day, year, hours, minutes and seconds
•
Press the knob to open the controller
•
Rotate the knob to choose the value
•
Press the knob again to close the controller
•
Rotate the knob to choose BACK and press to confirm and exit
5.1.6 Sensors:
For each engine parameter:
•
Confirm if you want to activate or disable the function on the display.
•
Confirm the sensor type that is installed on the connection board.
5.1.7 Settings Reset:
•
You will be asked for confirmation
•
Select OK and Press the knob to confirm
5.2 Alarms:
You can find here the recap of the alarms that have been activated with: status, value, date
and time (see table 3, Alarm Tags). Once you have read the alarm, press clear to remove
the exclamation mark from the data view pages. Rotate the knob to select OK and press to
confirm.
ALARM TAGS
NC
Sensor is not connected
S/C
Sensor is shorted
FAIL
Sensor is not working correctly
ALM HI
Alarm high, engine related alarm
WARN HI
Warning high, engine related alarm
WARN LO
Warning low, engine related alarm
ALM LO
Alarm low, engine related alarm
5.3 Export Data
Engine parameters are monitored with an update rate of five times per second. Data are
recorded and stored in the internal memory up to 160 hours.
In order to download the data log you can use:
•
The EngiBOX mobile app for iOS and Android (see chapter 7)
•
The microSD card (insert the microSD card into the EngiBOX and choose Export Data
to export the stored data from the device on the microSD card)
Note:
data can be stored on your EngiBOX Portal account for engine analysis (see chapter 8).
Table 3