Step Track Hold Tracking
AvL Technologies
| Proprietary – Content is Subject to Change without Notice
12
4.2.
Sensor Outputs
Path
Main Window → View→ Sensor Output
Level 0
Figure 6 - Sensor Outputs
Item
Level
Description
Current Signal Average
0
The average of the current signal
Current Signal Gradient
0
The rate of change of the current signal level
Current Signal Latched
Lock
0
Reports if modem ever locked.
Current Signal Level
0
The Signal to Noise ratio that is being reported by the modem in use.
This is the signal that the controller will use to peak on.
Current Signal Lock
0
If the signal is above the configured threshold
Current Signal Noise
0
The amount of noise in the current signal level.
Current Signal Source
0
The type of signal source being used to scan
Current Signal Type
0
The type of signal being picked up by scanning
Step Track Hold
Elevation Inc Average
0
Based on the Configuration item, “Elevation Inclinometer Counts”. This
is the Inclinometer averaged reading.
Step Track Hold Pedestal
Elevation Target
0
After a peaking cycle is complete, the pedestal Elevation axis is latched
for current cycle. This value is read here.
Step Track Hold Target
Elevation Inclinometer
0
Following peaking cycle, the actual inclinometer is read here.