Step Track Hold Tracking
AvL Technologies
| Proprietary – Content is Subject to Change without Notice
7
Cross Pattern Fine Signal
Tolerance
4
Float
0 – 1000
Signal degradation amount before a scan stops
Fine Peak Signal Difference
Threshold
4
Float
0.1 – 100
The amount of signal difference between peaking
iterations that will satisfy the system as the signal is
peaked
Fine Peaking Cycles
4
Float
0 – 100
Number of cycles to complete for fine peaking
Fine Peaking Maximum Cycles
4
Float
1 – 100
Maximum number of cycles to complete for fine
peaking stops
Fine Peaking Mode
4
Choice
CrossPattern/
StepPattern/
PlateauPeaking
Selection of the peaking method to use for fine
peaking routines
Plateau Peaking Fine Azimuth
Velocity
4
Float
0.02 – 0.5
Azimuth velocity in degrees/sec for fine peaking
Plateau Peaking Fine Elevation
Velocity
4
Float
0.02 – 0.5
Elevation velocity in degrees/sec for fine peaking
Step Pattern Fine Azimuth
Velocity
4
Float
0.02 – 0.5
Azimuth velocity in degrees/sec for fine peaking
Step Pattern Fine Elevation
Velocity
4
Float
0.01 – 0.5
Elevation velocity in degrees/sec for fine peaking
Step Pattern Fine Peaking
Azimuth Step
4
Float
0.02 – 0.5
Width in degrees to scan during a fine step pattern
peaking function
Step Pattern Fine Peaking
Elevation Step
4
Float
0.01 – 0.5
Height in degrees to scan during a fine step pattern
peaking function
3.4.
Feed Configuration Items
No feed configuration items are available for this module.